To set BERTs on ports
Example injecting a BERT toward the IP network
Parameter expected
Parameter choices: Off ToNet ToIf
[ctp_cmd@nova_47 ~ 43]> cmd port se-1/0 diag bert_tx ToNet
Example receiving a BERT from the IP network
Parameter expected
Parameter choices: Off FromNet FromIf
[ctp_cmd@nova_47 ~ 43]> cmd port se-1/0 diag bert_rx FromNet
Example setting the BERT pattern
Parameter expected
Parameter choices: MARK ALT 511 2047 2^15-1 2^20-1 2^23-1 2^29-1 2^31-1 2^4-1
[ctp_cmd@nova_47 ~ 49]> cmd port se-1/0 diag bert_pat 2^15-1
Example injecting a single error into the BERT
[ctp_cmd@nova_47 ~ 50]> cmd port se-1/0 diag bert_inj