control-ports
Syntax
Hierarchy Level
Release Information
Statement introduced in Junos OS Release 9.2. Support for dual control ports added in Junos OS Release 10.0.
Description
Enable the specific control port of the Services Processing Card (SPC) for use as a control link for the chassis cluster. By default, all control ports are disabled. User needs to configure a minimum of one control port per chassis of the cluster. If user configures port 0 only, the Juniper Services Redundancy Protocol process (jsrpd) does not send control heartbeats on control link 1 and the counters it sends will show zeroes.
Options
- fpc slot-number —Flexible
PIC Concentrator (FPC) slot number.
Note: FPC slot range depends on platform. The maximum range of 0 through 23 applies to SRX5800 devices; for SRX5600 devices, the only applicable range is 0 through 11; for SRX5400 devices, the applicable range is 0 through 5.
- port port-number —Port number on which to configure the control port.
Required Privilege Level
interface—To view this statement in the configuration.
interface-control—To add this statement to the configuration.