Navigation
Table of Contents
Guide That Contains This Content
[+] Expand All
[-] Collapse All
Supported Platforms
redundancy-interface-process
Syntax
redundancy-interface-process {command binary-file-path;disable; failover (alternate-media | other-routing-engine);}
Hierarchy Level
[edit system processes]
Release Information
Statement introduced in Junos OS Release 8.5.
Description
Specify as an active or backup process of an application server, configure to process traffic for more than one logical application server.
Options
- command binary-file-path—Path to the binary process.
- disable—Disable the redundancy interface management process.
- failover—Configure the device to reboot
if the software process fails four times within 30 seconds, and specify
the software to use during the reboot.
- alternate-media—Configure the device to switch to backup media that contains a version of the system if a software process fails repeatedly.
- other-routing-engine—Instruct the secondary Routing Engine to take mastership if a software process fails. If this statement is configured for a process, and that process fails four times within 30 seconds, then the device reboots from the secondary Routing Engine.
Required Privilege Level
system—To view this statement in the configuration.
system-control—To add this statement to the configuration.