Navigation
Supported Platforms
thresholds
Syntax
thresholds thresholds;
Hierarchy Level
[edit services rpm probe owner test test-name]
Release Information
Statement introduced before Junos OS Release 7.4.
Statement introduced in Junos OS Release 9.3 for EX Series switches.
Description
Specify thresholds used for the probes. A system log message is generated when the configured threshold is exceeded. Likewise, an SNMP trap (if configured) is generated when a threshold is exceeded.
Options
thresholds—Specify one or more threshold measurements. The following options are supported:
- egress-time—Measures maximum source-to-destination time per probe.
- ingress-time—Measures maximum destination-to-source time per probe.
- jitter-egress—Measures maximum source-to-destination jitter per test.
- jitter-ingress—Measures maximum destination-to- source jitter per test.
- jitter-rtt—Measures maximum jitter per test, from 0 through 60,000,000 microseconds.
- rtt—Measures maximum round-trip time per probe, in microseconds.
- std-dev-egress—Measures maximum source-to-destination standard deviation per test.
- std-dev-ingress—Measures maximum destination-to-source standard deviation per test.
- std-dev-rtt—Measures maximum standard deviation per test, in microseconds.
- successive-loss—Measures successive probe
loss count, indicating probe failure.
Default: 1
- total-loss—Measures total probe loss
count indicating test failure, from 0 through 15.
Default: 1
Required Privilege Level
interface—To view this statement in the configuration.
interface-control—To add this statement to the configuration.