Supported Platforms
Resetting Your Branch SRX Series
Resetting Your Branch SRX Series
Resetting Your SRX Series to a Rescue Configuration
If someone accidentally commits an invalid configuration file, you can delete the invalid configuration and replace it with a previously stored rescue configuration.
To reset your services gateway to its rescue configuration, use a small probe, such as a straightened paperclip, to press and immediately release the RESET CONFIG button. Your services gateway will load and commit the rescue configuration. During this operation, the Status light on the front panel of your services gateway glows amber.
Resetting Your SRX Series to Factory Settings
If resetting your device to its rescue configuration does not resolve your access problem, you can reset your services gateway to its factory-default configuration, which deletes all previous configurations and loads the device’s default settings.
To reset your services gateway to its factory-default configuration, use a small probe, such as a straightened paperclip, to press the RESET CONFIG button for 15 seconds or more.