Help us improve your experience.

Let us know what you think.

Do you have time for a two-minute survey?

Navigation

request chassis fpc

Syntax

request chassis fpc (offline | online | restart) slot slot-number

Syntax (TX Matrix and TX Matrix Plus Routers)

request chassis fpc (offline | online | restart) slot slot-number<lcc number>

Syntax (MX Series Routers)

request chassis fpc (offline | online | restart) slot slot-number<all-members><local><member member-id>

Syntax (MX2020 3D Universal Edge Routers)

request chassis fpc (offline | online | restart) slot slot-number

Syntax (MX2010 3D Universal Edge Routers)

request chassis fpc (offline | online | restart) slot slot-number

Syntax (QFabric System)

request chassis fpc<interconnect-device name slot slot-number (offline | online)><(offline | online) interconnect-device name slot slot-number><slot slot-number interconnect-device name (offline | online)>

Syntax (PTX Series Packet Transport Switches)

request chassis fpc (offline | online | restart) slot slot-number

Release Information

Command introduced before Junos OS Release 7.4.

Command introduced in Junos OS Release 9.0 for EX Series switches.

Command introduced in Junos OS 11.3 for QFX Series.

Command introduced in Junos OS 12.1 for PTX Series Packet Transport Switches.

Command introduced in Junos OS Release 12.3 for MX2020 3D Universal Edge Routers.

Command introduced in Junos OS Release 12.3 for MX2010 3D Universal Edge Routers.

Description

(M20, M40, M40e, M120, M160, M320, MX Series, and T Series routers, QFabric systems, EX Series switches, and PTX Series Packet Transport Switches only) Control the operation of the Flexible PIC Concentrator (FPC). For information about the meaning of “FPCs” on the switches, see EX Series Switches Hardware and CLI Terminology Mapping.

Note: Beginning in Junos OS 12.3, it is possible that FPCs brought offline using the request chassis fpc slot fpc-slot offline operational-mode CLI command can come online during a configuration commit or power-supply replacement procedure. As an alternative, use the set fpc fpc-slot power off configuration-mode command at the [edit chassis] hierarchy level to ensure that the FPCs remain offline.

Options

offline

Take the FPC offline.

online

Bring the FPC online.

interconnect-device name

(QFabric systems only) Bring the Flexible Port Concentrator (FPC) on the QFX3008-I Interconnect device either offline or online:

  • (QFabric System) On a QFabric system, specify the name of the QFX3008-I Interconnect device containing the Flexible Port Concentrator (FPC) you want to bring either offline or online.
restart

Restart the FPC.

slot slot-number

FPC slot number:

  • M20 router—0 through 3.
  • M120 router—0 through 5.
  • MX240 router—0 through 2. On the MX240 router, slot-number corresponds to the Dense Port Concentrator (DPC) slot number. If an MPC is installed, slot-number corresponds to the MPC slot number.
  • MX480 router—0 through 5. On the MX480 router, slot-number corresponds to the Dense Port Concentrator (DPC) slot number. If an MPC is installed, slot-number corresponds to the MPC slot number.
  • MX960 router—0 through 11. On the MX960 router, slot-number corresponds to the Dense Port Concentrator (DPC) slot number. If an MPC is installed, slot-number corresponds to the MPC slot number.
  • MX2020 router—0 through 19.
  • MX2010 router—0 through 9.
  • TX Matrix and TX Matrix Plus routers only—On the TX Matrix router, if you specify the number of the T640 router by using the lcc number option (the recommended method), replace slot-number with a value from 0 through 7. Otherwise, replace slot-number with a value from 0 through 31.

    Likewise, on a TX Matrix Plus router, if you specify the number of the T1600 router by using the lcc number option (the recommended method), replace slot-number with a value from 0 through 7. Otherwise, replace slot-number with a value from 0 through 31. For example, the following commands have the same result:

    user@host> request chassis fpc lcc 1 slot 1 offlineuser@host> request chassis fpc slot 9 offline
  • Other routers—0 through 7.
  • QFabric System—Replace slot-number with a value from 0 through 2.
  • EX Series switches:
    • EX4200 switches in a Virtual Chassis configuration—Replace slot-number with a value from 0 through 9.
    • EX6210 switches—Replace slot-number with a value from 0 through 9.

      Note: These commands are not supported for slots 4 and 5 when a Switch Fabric and Routing Engine (SRE) module is installed in those slots. These commands are supported for slots 4 and 5 only if a line card is installed in them.

    • EX8208 switches—Replace slot-number with a value from 0 through 7.
    • EX8216 switches—Replace slot-number with a value from 0 through 15.
  • PTX5000 Packet Transport Switch—Replace slot-number with a value from 0 through 7.
all-members

(MX Series routers only) (Optional) Change FPC status of all members of the Virtual Chassis configuration.

local

(MX Series routers only) (Optional) Change FPC status of the local Virtual Chassis member.

member member-id

(MX Series routers only) (Optional) Change FPC status of the specified member of the Virtual Chassis configuration. Replace member-id with a value of 0 or 1.

lcc number

(TX Matrix and TX Matrix Plus routers only) (Optional) On a TX Matrix router, control the FPC in a specified T640 router that is connected to the TX Matrix router. On a TX Matrix Plus router, control the FPC in a specified T1600 router that is connected to the TX Matrix Plus router. Replace number with a value from 0 through 3.

Required Privilege Level

maintenance

List of Sample Output

request chassis fpc
request chassis fpc (MX Series Routers with Media Services Blade [MSB])
request chassis fpc (MX2020 Router)
request chassis fpc (MX2010 Router)

Output Fields

When you enter this command, you are provided feedback on the status of your request.

Sample Output

request chassis fpc

user@host> request chassis fpc online slot 0
FPC 0 already online

request chassis fpc (MX Series Routers with Media Services Blade [MSB])

user@host> request chassis fpc slot 0
Possible completions:
  offline              Take FPC offline
  online               Bring FPC online
  restart              Restart FPC

request chassis fpc (MX2020 Router)

user@host >request chassis fpc online slot 2
FPC 2 already online

request chassis fpc (MX2010 Router)

user@host >request chassis fpc offline slot 5
Offline initiated, use "show chassis fpc" to verify

Published: 2014-03-26