request chassis mic
Syntax
Release Information
Command introduced in Junos OS Release 10.1.
Command introduced in Junos OS Release 12.3 for ACX4000 Series Router.
Command introduced in Junos OS Release 12.3 for MX2020 3D Universal Edge Routers.
Command introduced in Junos OS Release 12.3 for MX2010 3D Universal Edge Routers.
Description
(MX Series routers only) Control the operation of the Modular Interface Cards (MICs) installed on a Modular Port Concentrator (MPC).
![]() | Note: On MX960 routers, if the MIC is not functioning correctly, you should take the MPC offline, replace it with a new MPC, and reinstall the MIC. |
Options
offline | — | Take the MIC offline. |
online | — | Bring the MIC online. |
fpc-slot slot-number | — | FPC slot number where the MIC is installed:
|
mic-slot slot-number | — | MIC slot number. Replace slot-number with 0 or 1. |
Required Privilege Level
maintenance
List of Sample Output
request chassis mic onlinerequest chassis mic (MX Routers with Media Services Blade [MSB])
request chassis mic onine (MX2010 Router)
Output Fields
When you enter this command, you are provided feedback on the status of your request.
Sample Output
request chassis mic online
user@host> request chassis mic online fpc-slot
1 mic-slot 1
request chassis mic (MX Routers with Media Services Blade [MSB])
user@host> request chassis mic fpc-slot 1 mic-slot
0
Possible completions: offline Take MIC offline online Bring MIC online
request chassis mic onine (MX2010 Router)
user@host> request chassis mic online fpc-slot 1 mic-slot 0
FPC 1, MIC 0 is already online