falling-threshold

Syntax

falling-threshold integer;

Hierarchy Level

[edit snmp rmon alarm index]

Release Information

Statement introduced before Junos OS Release 7.4.

Statement introduced in Junos OS Release 9.0 for EX Series switches.

Description

The lower threshold for the sampled variable. When the current sampled value is less than or equal to this threshold, and the value at the last sampling interval is greater than this threshold, a single event is generated. A single event is also generated if the first sample after this entry becomes valid is less than or equal to this threshold, and the associated startup-alarm value is equal to falling-alarm value or rising-or-falling-alarm value. After a falling event is generated, another falling event cannot be generated until the sampled value rises above this threshold and reaches the rising-threshold.

Options

integer—The lower threshold for the alarm entry.

Range: -2,147,483,648 through 2,147,483,647

Default: 20 percent less than rising-threshold

Required Privilege Level

snmp—To view this statement in the configuration.

snmp-control—To add this statement to the configuration.

Published: 2012-12-08