minimum-receive-interval

Syntax

minimum-receive-interval milliseconds;

Hierarchy Level

[edit protocols pim interface interface-name bfd-liveness-detection],[edit routing-instances routing-instance-name protocols pim interface interface-name bfd-liveness-detection]

Release Information

Statement introduced in Junos OS Release 8.1.

Statement introduced in Junos OS Release 9.0 for EX Series switches.

Statement introduced in Junos OS Release 12.1 for the QFX Series.

Description

Configure the minimum interval after which the local routing device must receive a reply from a neighbor with which it has established a BFD session. Optionally, instead of using this statement, you can configure the minimum receive interval using the minimum-interval statement at the [edit protocols pim interface interface-name bfd-liveness-detection] hierarchy level.

Options

milliseconds—Minimum receive interval.

Range: 1 through 255,000 milliseconds

Required Privilege Level

routing—To view this statement in the configuration.

routing-control—To add this statement to the configuration.

 
 

Published: 2013-04-03

 
 