Supported Platforms
Related Documentation
quality-level (Clock Class Mapping PTP Slave)
Syntax
Hierarchy Level
Release Information
Statement introduced in Junos OS Release 12.1.
Statement introduced in Junos OS Release 12.2 for ACX Series Routers.
Description
Configure the quality level for the timing source so that the router knows the best available source with which to synchronize. The quality level specifies the accuracy level of the clock.
Options
prc—Timing quality of a primary reference clock (option-1 only).
prs—Clock traceable to a primary reference source (option-2 only).
sec—Timing quality of an SDH equipment clock (option-1 only).
smc— Clock traceable to a self-timed SONET (option-2 only).
ssu-a—Timing quality of a type I or IV slave clock (option-1 only).
ssu-b—Timing quality of a type VI slave clock (option-1 only).
st2—Clock traceable to Stratum 2 (option-2 only).
st3—Clock traceable to Stratum 3 (option-2 only).
st3e—Clock traceable to Stratum 3E (option-2 only).
st4—Clock traceable to Stratum 4 free-run (option-2 only).
stu—Clock traceable to an unknown quality (option-2 only).
tnc—Clock traceable to a transit node clock (option-2 only).
Required Privilege Level
routing—To view this statement in the configuration.
routing-control—To add this statement to the configuration.