Navigation
revert-time (Interfaces)
Syntax
revert-time seconds;
Hierarchy Level
[edit interfaces interface-name sonet-options aps]
Release Information
Statement introduced before Junos OS Release 7.4.
Description
Configure APS revertive mode.
Default
APS operates in nonrevertive mode.
Options
seconds—Amount of time to wait after the working circuit has again become functional before making the working circuit active again.
Range: 1 through 65,535 seconds
Default: None (APS operates in nonrevertive mode)
Required Privilege Level
interface—To view this statement in the configuration.
interface-control—To add this statement to the configuration.