rising-threshold (SNMP Health Monitor)
Syntax
Hierarchy Level
Release Information
Statement introduced in Junos OS Release 8.0.
Statement introduced in Junos OS Release 9.0 for EX Series switches.
Description
The upper threshold is expressed as a percentage of the maximum possible value for the sampled variable. When the current sampled value is greater than or equal to this threshold, and the value at the last sampling interval is less than this threshold, a single event is generated. A single event is also generated if the first sample after this entry becomes valid is greater than or equal to this threshold. After a rising event is generated, another rising event cannot be generated until the sampled value falls below this threshold and reaches the falling-threshold.
Options
percentage—The lower threshold for the alarm entry.
Range: 1 through 100
Default: 80 percent of the maximum possible value
Required Privilege Level
snmp—To view this statement in the configuration.
snmp-control—To add this statement to the configuration.