Supported Platforms
symbol-period
Syntax
Hierarchy Level
Release Information
Statement introduced in Junos OS Release 9.4 for EX Series switches.
Description
Configure the threshold for sending symbol period events or taking the action specified in the action profile.
Symbol code errors occur on the underlying physical layer. The symbol period threshold is reached when the number of symbol errors reaches the configured value within the period. You cannot configure the default value to a different value.
Options
count—Threshold count in seconds for symbol period events.
Range: 1 through 100 seconds
Required Privilege Level
routing—To view this statement in the
configuration.
routing-control—To add this statement
to the configuration.