falling-threshold-interval

Syntax

falling-threshold-interval seconds;

Hierarchy Level

[edit snmp rmon alarm index]

Release Information

Statement introduced in Junos OS Release 11.1 for the QFX Series.

Description

Set the interval between samples after the rising threshold is exceeded and the value of the sample starts to drop. If the value of the sample drops and exceeds the falling threshold, the regular sampling interval is used.

Options

interval—Time between samples, in seconds.

Range: 1 through 2,147,483,647 seconds

Default: 60 seconds

Required Privilege Level

snmp—To view this statement in the configuration.

snmp-control—To add this statement to the configuration.