Syntax

tacplus-options {(exclude-cmd-attribute | no-cmd-attribute-value);service-name service-name;timestamp-and-timezone;}

Hierarchy Level

[edit system]

Release Information

Statement introduced before Junos OS Release 7.4.

Statement introduced in Junos OS Release 9.0 for EX Series switches.

Options for no-cmd-attribute-value and exclude-cmd-attribute introduced in Junos OS Release 9.3.

Statement introduced in Junos OS Release 11.1 for QFX Series.

Option for timestamp-and-timezone introduced in Junos OS Release 12.2.

Description

Configure TACACS+ options for authentication and accounting.

Options

exclude-cmd-attribute—Exclude the cmd attribute value completely from start and stop accounting records to enable logging of accounting records in the correct log file on a TACACS+ server.

no-cmd-attribute-value—Set the cmd attribute value to an empty string in the TACACS+ accounting start and stop requests to enable logging of accounting records in the correct log file on a TACACS+ server.

service-name service-name—Name of the authentication service used when you configure multiple TACACS+ servers to use the same authentication service.

Default: junos-exec

timestamp-and-timezone—Include this statement if you want start time, stop time, and timezone attributes included in start/stop accounting records.

Required Privilege Level

system—To view this statement in the configuration.

system-control—To add this statement to the configuration.