Log the Chassis Environment Information

Action

To log the router chassis environment information, use the following Junos OS CLI operational mode command:

user@host> show chassis environment | save filename

Sample Output

The following example shows output from the show chassis environment command for an M5 router:

user@m5-host> show chassis environment | save test
Wrote 14 lines of output to ‘test’

user@m5-host> show chassis environment 
Class Item                   Status     Measurement
Power Power Supply A         OK
      Power Supply B         OK
Temp  FPC Slot 0             OK         32 degrees C / 89 degrees F
      FEB                    OK         31 degrees C / 87 degrees F
      PS Intake              OK         26 degrees C / 78 degrees F
      PS Exhaust             OK         31 degrees C / 87 degrees F
Fans  Left Fan 1             OK         Spinning at normal speed
      Left Fan 2             OK         Spinning at normal speed
      Left Fan 3             OK         Spinning at normal speed
      Left Fan 4             OK         Spinning at normal speed

Meaning

The sample output shows the environmental information about the router chassis, including the temperature and information about the fans, power supplies, and Routing Engine.