request virtual-chassis vc-port
Syntax
Release Information
Command introduced in Junos OS Release 9.0 for EX Series switches.
Option fpc-slot introduced in Junos OS Release 10.4 for EX Series switches.
Command introduced in Junos OS Release 13.2X50-D15 for the QFX Series.
Command introduced in Junos OS Release 13.2X51-D20 for Virtual Chassis Fabric (VCF).
Description
Enable or disable an optical port as a Virtual Chassis port (VCP).
If you omit member member-id, this command defaults to enabling or disabling the uplink VCP or SFP network port configured as a VCP on the switch where the command is issued.
On an EX3300 switch, uplink ports 2 and 3 are configured as VCPs by default. No other uplink ports on any other EX Series switches are configured as VCPs by default.
You might experience a temporary traffic disruption immediately after creating or deleting a user-configured VCP in an EX8200 Virtual Chassis.
Options
pic-slot pic-slot | — | Number of the PIC slot for the port on the switch. |
port port-number | — | Number of the port that is to be enabled or disabled as a VCP. |
member member-id | — | (Optional) Enable or disable the specified VCP on the specified member of the Virtual Chassis or VCF. |
Required Privilege Level
system-control
Related Documentation
- EX Series
- request virtual-chassis vc-port (dedicated port)
- Virtual Chassis Port (VCP) Interface Names in an EX8200 Virtual Chassis
- Understanding EX Series Virtual Chassis Components
- EX Series, QFX Series standalone switches
- show virtual-chassis vc-port
- show virtual-chassis vc-port statistics
- clear virtual-chassis vc-port statistics
- QFX Series standalone switches
- Understanding QFX Series Virtual Chassis Components
List of Sample Output
request virtual-chassis vc-port set pic-slot 1 port 0request virtual-chassis vc-port set pic-slot 1 port 1 member 3
request virtual-chassis vc-port delete pic-slot 1 port 1 member 3
Sample Output
request virtual-chassis vc-port set pic-slot 1 port 0
user@switch> request virtual-chassis vc-port
set pic-slot 1 port 0
To check the results of this command, use the show virtual-chassis vc-port command.
request virtual-chassis vc-port set pic-slot 1 port 1 member 3
user@switch> request virtual-chassis vc-port
set pic-slot 1 port 1 member 3
To check the results of this command, use the show virtual-chassis vc-port command.
request virtual-chassis vc-port delete pic-slot 1 port 1 member 3
user@switch> request virtual-chassis vc-port
delete pic-slot 1 port 1 member 3
To check the results of this command, use the show virtual-chassis vc-port command.
Published: 2014-04-29
Supported Platforms
Related Documentation
- EX Series
- request virtual-chassis vc-port (dedicated port)
- Virtual Chassis Port (VCP) Interface Names in an EX8200 Virtual Chassis
- Understanding EX Series Virtual Chassis Components
- EX Series, QFX Series standalone switches
- show virtual-chassis vc-port
- show virtual-chassis vc-port statistics
- clear virtual-chassis vc-port statistics
- QFX Series standalone switches
- Understanding QFX Series Virtual Chassis Components