clock-client (Master Clock)

Syntax

clock-client ip-address local-ip-address local-ip-address {manual;}

Hierarchy Level

[edit protocols ptp master interface interface-name unicast-mode]

Release Information

Statement introduced in Junos OS Release 12.3 for ACX Series Routers.

Description

Configure the IP address or subnet of the remote PTP host and the local PTP master interface. This statement enables you to specify the following information:

  • The exact IP address of a PTP host
  • A subnet mask instead of the exact IP address of each host. The ACX Series router acting as the master boundary clock processes unicast negotiation requests from any host—within the subnet—which sends unicast negotiation requests. The maximum number of clock clients is 512.

    Note: You can configure the maximum number of clients (512 ) in the following combination:

    • Automatic clients 256.
    • Manual and secure clients 256—Any combination of manual and secure clients is allowed as long as the combined total amounts to 256.

Options

ip-address

IP address or subnet of the remote PTP host.

local-ip-address

IP address of the local PTP master interface.

The remaining statement is explained separately.

Required Privilege Level

routing—To view this statement in the configuration.

routing-control—To add this statement to the configuration.