cycle-time
Syntax
cycle-time cycle-time-value;
Hierarchy Level
[edit protocols oam ethernet connectivity-fault-management performance-monitoring sla-iterator-profiles profile-name]
Release Information
Statement introduced in Junos OS Release 11.1.
Statement introduced in Junos OS Release 11.4 for EX Series switches.
Description
Configure the time (in milliseconds) taken between back-to-back transmissions of SLA frames for a single connection.
Options
cycle-time-value—Cycle time value in milliseconds.
Range: 10 through 3,600,000
Default: 1000