Help us improve your experience.

Let us know what you think.

Do you have time for a two-minute survey?

Navigation

link-down

Syntax

link-down (red | yellow | ignore);

Hierarchy Level

[edit chassis alarm ethernet],[edit chassis alarm fibre-channel],[edit chassis interconnect-device name alarm ethernet],[edit chassis node-group name alarm fibre-channel]

Release Information

Statement introduced in Junos OS Release 11.3 for the QFX Series.

Description

Specify either red, yellow, or ignore to display when the link is down.

Options

red

Indicates that one or more hardware components have failed or exceeded temperature thresholds, or an alarm condition configured on an interface has triggered a critical warning.

yellow

Indicates a noncritical condition on the device that, if left unchecked, might cause an interruption in service or degradation in performance. A yellow alarm condition requires monitoring or maintenance.

ignore

Suppresses or ignores the alarm.

Required Privilege Level

routing—To view this statement in the configuration.
routing-control—To add this statement to the configuration.

Published: 2014-07-23