lmi (Frame Relay)

Syntax

lmi {lmi-type (ansi | itu | c-lmi);n391dte number;n392dce seconds;n392dte number;n393dce number;n393dte number;t391dte number;t392dce seconds;}

Hierarchy Level

[edit interfaces interface-name]

Release Information

Statement introduced before Junos OS Release 7.4.

Description

Set Frame Relay keepalive parameters.

Options

n391dte—DTE full status polling interval.

Range: 1 through 255

Default: 6

n392dce—DCE error threshold, in number of errors.

Range: 1 through 10

Default: 3

n392dte—DTE error threshold, in number of errors.

Range: 1 through 10

Default: 3

n393dce—DCE monitored event-count.

Range: 1 through 10

Default: 4

n393dte—DTE monitored event-count.

Range: 1 through 10

Default: 4

t391dte—DTE polling timer.

Range: 5 through 30 seconds

Default: 10 seconds

t392dce—DCE polling timer.

Range: 5 through 30 seconds

Default: 15 seconds

The remaining statements are explained separately.

Required Privilege Level

interface—To view this statement in the configuration.

interface-control—To add this statement to the configuration.