Supported Platforms
Related Documentation
lmi (Frame Relay)
Syntax
Hierarchy Level
Release Information
Statement introduced before Junos OS Release 7.4.
Description
Set Frame Relay keepalive parameters.
Options
n391dte—DTE full status polling interval.
Range: 1 through 255
Default: 6
n392dce—DCE error threshold, in number of errors.
Range: 1 through 10
Default: 3
n392dte—DTE error threshold, in number of errors.
Range: 1 through 10
Default: 3
n393dce—DCE monitored event-count.
Range: 1 through 10
Default: 4
n393dte—DTE monitored event-count.
Range: 1 through 10
Default: 4
t391dte—DTE polling timer.
Range: 5 through 30 seconds
Default: 10 seconds
t392dce—DCE polling timer.
Range: 5 through 30 seconds
Default: 15 seconds
The remaining statements are explained separately.
Required Privilege Level
interface—To view this statement in the configuration.
interface-control—To add this statement to the configuration.