minimum-interval (Liveness Detection)
Syntax
Hierarchy Level
Release Information
Statement introduced in Junos OS Release 10.0 for MX Series routers.
Statement introduced in Junos OS Release 12.2 for the QFX Series.
Statement introduced in Junos OS Release 12.3R2 for EX Series switches.
Description
Configure simultaneously the minimum interval at which the peer transmits liveness detection requests and the minimum interval at which the peer expects to receive a reply from a peer with which it has established a Bidirectional Forwarding Detection (BFD) session. Optionally, instead of using this statement, you can specify the minimum transmit and receive intervals separately by using the transmit-interval minimal-interval and minimum-receive-interval statements, respectively.
Options
milliseconds—Specify the minimum interval value for Bidirectional Forwarding Detection (BFD).
Range: 1 through 255,000
Required Privilege Level
routing—To view this statement in the configuration.
routing-control—To add this statement to the configuration.