polling-interval
Syntax
Hierarchy Level
Release Information
Statement introduced in Junos OS Release 11.3 for the QFX Series.
Description
Configure the rate (in seconds) at which successive samples of interface statistics (counters) are taken.
Default
If no polling interval is configured for a particular interface, the device uses the global polling interval configured at the [edit protocols sflow] hierarchy level. If no global interval is configured, the device uses the default polling interval of 20 seconds.
Options
seconds—Number of seconds between successive samples of interface statistics. Specifying a value of 0 (zero) disables the polling.
Range: 0 through 3600 seconds