rising-threshold (SNMP RMON)
Syntax
Hierarchy Level
Release Information
Statement introduced before Junos OS Release 7.4.
Statement introduced in Junos OS Release 9.0 for EX Series switches.
Description
Upper threshold for the sampled variable. When the current sampled value is greater than or equal to this threshold, and the value at the last sampling interval is less than this threshold, a single event is generated. A single event is also generated if the first sample after this entry becomes valid is greater than or equal to this threshold, and the associated startup alarm value is equal to the falling alarm or rising or falling alarm value. After a rising event is generated, another rising event cannot be generated until the sampled value falls below this threshold and reaches the falling threshold.
Options
integer—The lower threshold for the alarm entry.
Range: –2,147,483,648 through 2,147,483,647
Required Privilege Level
snmp—To view this statement in the configuration.