jnxDomAlarmId specifies the DOM alarms present on an interface. The possible values are:

  • domRxLossSignalAlarm(0)—Input loss of signal
  • domRxCDRLossLockAlarm(1)—Input loss of lock
  • domRxNotReadyAlarm(2)—Input rx path
  • domRxLaserPowerHighAlarm(3)—High input laser power
  • domRxLaserPowerLowAlarm(4)—Low input laser power
  • domTxLaserBiasCurrentHighAlarm(5)—High output laser bias current
  • domTxLaserBiasCurrentLowAlarm(6)—Low output laser bias current
  • domTxLaserOutputPowerHighAlarm(7)—High output laser power
  • domTxLaserOutputPowerLowAlarm(8)—Low output laser power
  • domTxDataNotReadyAlarm(9)—Output A/D data not ready
  • domTxNotReadyAlarm(10)—Output tx path
  • domTxLaserFaultAlarm(11)—Output laser safety
  • domTxCDRLossLockAlarm(12)—Output clock data recovery
  • domModuleTemperatureHighAlarm(13)—High module temperature
  • domModuleTemperatureLowAlarm(14)—Low module temperature
  • domModuleNotReadyAlarm(15)—Module not ready
  • domModulePowerDownAlarm(16)—Module P_DOWN
  • domLinkDownAlarm(17)—Wire unplugged or down
  • domModuleRemovedAlarm(18)—Module unplugged or down

jnxDomWarningId specifies the DOM warnings present on an interface. The possible values are:

  • domRxLaserPowerHighWarning(0)—High input laser power
  • domRxLaserPowerLowWarning(1)—Low input laser power
  • domTxLaserBiasCurrentHighWarning(2)—High output laser bias current
  • domTxLaserBiasCurrentLowWarning(3)—Low output laser bias current
  • domTxLaserOutputPowerHighWarning(4)—High output laser power
  • domTxLaserOutputPowerLowWarning(5)—Low output laser power
  • domModuleTemperatureHighWarning(6)—High module temperature
  • domModuleTemperatureLowWarning(7)—Low module temperature