DOM MIB Textual Conventions
jnxDomAlarmId specifies the DOM alarms present on an interface. The possible values are:
- domRxLossSignalAlarm(0)—Input loss of signal
- domRxCDRLossLockAlarm(1)—Input loss of lock
- domRxNotReadyAlarm(2)—Input rx path
- domRxLaserPowerHighAlarm(3)—High input laser power
- domRxLaserPowerLowAlarm(4)—Low input laser power
- domTxLaserBiasCurrentHighAlarm(5)—High output laser bias current
- domTxLaserBiasCurrentLowAlarm(6)—Low output laser bias current
- domTxLaserOutputPowerHighAlarm(7)—High output laser power
- domTxLaserOutputPowerLowAlarm(8)—Low output laser power
- domTxDataNotReadyAlarm(9)—Output A/D data not ready
- domTxNotReadyAlarm(10)—Output tx path
- domTxLaserFaultAlarm(11)—Output laser safety
- domTxCDRLossLockAlarm(12)—Output clock data recovery
- domModuleTemperatureHighAlarm(13)—High module temperature
- domModuleTemperatureLowAlarm(14)—Low module temperature
- domModuleNotReadyAlarm(15)—Module not ready
- domModulePowerDownAlarm(16)—Module P_DOWN
- domLinkDownAlarm(17)—Wire unplugged or down
- domModuleRemovedAlarm(18)—Module unplugged or down
jnxDomWarningId specifies the DOM warnings present on an interface. The possible values are:
- domRxLaserPowerHighWarning(0)—High input laser power
- domRxLaserPowerLowWarning(1)—Low input laser power
- domTxLaserBiasCurrentHighWarning(2)—High output laser bias current
- domTxLaserBiasCurrentLowWarning(3)—Low output laser bias current
- domTxLaserOutputPowerHighWarning(4)—High output laser power
- domTxLaserOutputPowerLowWarning(5)—Low output laser power
- domModuleTemperatureHighWarning(6)—High module temperature
- domModuleTemperatureLowWarning(7)—Low module temperature