minimum-priority

Syntax

minimum-priority value;

Hierarchy Level

[edit services dynamic-flow-capture capture-group client-name control-source identifier]

Release Information

Statement introduced in JUNOS Release 9.2.

Description

Specify the minimum priority for the control source.

Options

value—Minimum priority value; if not specified, defaults to 0.

Range: 0 through 254

Usage Guidelines

See Configuring Dynamic Flow Capture.

Required Privilege Level

interface—To view this statement in the configuration.

interface-control—To add this statement to the configuration.