Statement introduced before JUNOS Release 7.4.
For multilink interfaces only, set the length of the packet sequence identification number to 12 bits.
If not included in the configuration, the length is set to 24 bits.
See Configuring the Sequence Header Format on Multilink and Link Services Logical Interfaces.
interface—To view this statement in the configuration.
interface-control—To add this statement to the configuration.