Specify thresholds used for the probes. A system
log message is generated when the configured threshold is exceeded.
Likewise, an SNMP trap (if configured) is generated when a threshold
is exceeded.
Options
thresholds—Specify
one or more threshold measurements. The following options are supported:
egress-time—Measures maximum source-to-destination
time per probe.
ingress-time—Measures maximum destination-to-source
time per probe.
jitter-egress—Measures maximum source-to-destination
jitter per test.
jitter-ingress—Measures maximum destination-to-
source jitter per test.
jitter-rtt—Measures maximum jitter per
test, from 0 through 60,000,000 microseconds.
rtt—Measures maximum round-trip time per
probe, in microseconds.
std-dev-egress—Measures maximum source-to-destination
standard deviation per test.
std-dev-ingress—Measures maximum destination-to-source
standard deviation per test.
std-dev-rtt—Measures maximum standard deviation
per test, in microseconds.
successive-loss—Measures successive probe
loss count, indicating probe failure.
total-loss—Measures total probe loss count
indicating test failure, from 0 through 15.