- [edit services pgcp gateway gateway-name h248-properties hanging-termination-detection]
Statement introduced in JUNOS Release 9.2.
Activate and configure hanging termination detection. Setting this timer to a value other than zero (0) activates hanging termination detection. If no messages are exchanged between the BGF and the gateway controller for a termination before this time expires, the BGF sends a notification to the gateway controller. The timer resets when the BGF and the gateway controller exchange a message for the termination. The timer value that you set is the default value, and can be overridden by H.248 messages sent from the gateway controller.
Your configuration takes effect on new and modified terminations.
seconds—Number of seconds between the last message exchanged for this termination and when the BGF sends a notification to the gateway controller. Setting the timer to zero (0) deactivates hanging termination detection.
interface—To view this statement in the configuration.
interface-control—To add this statement to the configuration.
JUNOS Multiplay Solutions Guide