Pluggable Transceivers Supported on EX Series Switches

date_range 05-Oct-18

The transceivers for EX Series switches are hot-removable and hot-insertable field-replaceable units (FRUs): You can remove and replace them without powering off the switch or disrupting switch functions.

Note

After you insert a transceiver or after you change the media-type configuration, wait for 6 seconds for the interface to display the operational commands.

Note

We recommend that you use only optical transceivers and optical connectors purchased from Juniper Networks with your Juniper Networks device.

Caution

If you face a problem running a Juniper Networks device that uses a third-party optic or cable, the Juniper Networks Technical Assistance Center (JTAC) can help you diagnose the source of the problem. Your JTAC engineer might recommend that you check the third-party optic or cable and potentially replace it with an equivalent Juniper Networks optic or cable that is qualified for the device.

  • EX2200—Uplink ports and dual-purpose uplink ports on the front panel in EX2200 switches support SFP transceivers. You can find the list of transceivers supported on EX2200 switches and information about those transceivers at the Hardware Compatibility Tool page for EX2200.

    Note

    EX2200-C switches ensure normal operation in the temperature range 30° F (0° C) through 104° F (40° C) at altitudes up to 5,000 ft (1,524 m).
    In the following conditions, use extended temperature range SFP transceivers when fiber uplinks are used:

    • In the temperature range 104° F (40° C) through 113° F (45° C) at altitudes up to 5,000 ft (1,524 m)

    • In the temperature range 95° F (35° C) through 113° F (45° C) at altitudes above 5,000 ft (1,524 m) up to 10,000 ft (3,048 m)

  • You can find the list of transceivers supported on EX2300 switches except EX2300-24MP and EX2300-48MP and information about those transceivers at the Hardware Compatibility Tool page for EX2300.

    You can find the list of transceivers supported on EX2300-24MP and EX2300-48MP switches and information about those transceivers at the Hardware Compatibility Tool page for EX2300 Multigigabit.

    Note

    EX2300-C switches ensure normal operation in the temperature range 32° F (0° C) through 104° F (40° C) at altitudes up to 5,000 ft (1,524 m).
    In the temperature range 104° F (40° C) through 113° F (45° C) at altitudes up to 5,000 ft (1,524 m), use extended temperature range SFP transceivers.

    The Gigabit Ethernet SFP and SFP+ transceivers installed in EX2300 switches support digital optical monitoring (DOM): You can view the diagnostic details for these transceivers by issuing the operational mode CLI command show interfaces diagnostics optics.

    Note

    The transceivers support DOM even if they are installed in uplink ports configured as Virtual Chassis ports.

  • EX3200—Optional uplink modules for EX3200 switches support SFP, SFP+, or XFP transceivers. You can find the list of transceivers supported on EX3200 switches and information about those transceivers at the Hardware Compatibility Tool page for EX3200.

    The Gigabit Ethernet SFP, SFP+, or XFP transceivers installed in EX3200 switches support digital optical monitoring (DOM): You can view the diagnostic details for these transceivers by issuing the operational mode CLI command show interfaces diagnostics optics.

  • EX3300—Uplink ports on the front panel in EX3300 switches support SFP and SFP+ transceivers. You can find the list of transceivers supported on EX3300 switches and information about those transceivers at the Hardware Compatibility Tool page for EX3300.

    The Gigabit Ethernet SFP and SFP+ transceivers installed in EX3300 switches support digital optical monitoring (DOM): you can view the diagnostic details for these transceivers by issuing the operational mode CLI command show interfaces diagnostics optics.

    Note

    The transceivers support DOM even if they are installed in uplink ports configured as Virtual Chassis ports.

  • EX3400—Uplink ports on EX3400 switches support SFP, SFP+, and QSFP+ transceivers. You can find the list of transceivers supported on EX3400 switches and information about those transceivers at the Hardware Compatibility Tool page for EX3400.

    The Gigabit Ethernet SFP, SFP+, and QSFP+ transceivers installed in EX3400 switches support digital optical monitoring (DOM): You can view the diagnostic details for these transceivers by issuing the operational mode CLI command show interfaces diagnostics optics.

    Note

    The transceivers support DOM even if they are installed in uplink ports configured as Virtual Chassis ports.

  • EX4200—Optional uplink modules for EX4200 switches support SFP, SFP+, or XFP transceivers. You can find the list of transceivers supported on EX4200 switches and information about those transceivers at the Hardware Compatibility Tool page for EX4200.

    The Gigabit Ethernet SFP, SFP+, or XFP transceivers installed in EX4200 switches support digital optical monitoring (DOM): You can view the diagnostic details for these transceivers by issuing the operational mode CLI command show interfaces diagnostics optics.

    Note

    The transceivers support DOM even if they are installed in uplink module ports configured as Virtual Chassis ports.

  • You can find the list of transceivers supported on EX4300 switches except EX4300-48MP and EX4300-48MP-S switches and information about those transceivers at the Hardware Compatibility Tool page for EX4300.

    You can find the list of transceivers supported on EX4300-48MP and EX4300-48MP-S switches and information about those transceivers at the Hardware Compatibility Tool page for EX4300 Multigigabit.

    The Gigabit Ethernet transceivers installed in EX4300 switches support digital optical monitoring (DOM): You can view the diagnostic details for these transceivers by issuing the operational mode CLI command show interfaces diagnostics optics.

    Note

    The transceivers support DOM even if they are installed in ports configured as Virtual Chassis ports (VCPs).

  • EX4500—Uplink module ports on EX4500 switches support SFP and SFP+ transceivers. You can find the list of transceivers supported on EX4500 switches and information about those transceivers at the Hardware Compatibility Tool page for EX4500.

    The Gigabit Ethernet SFP and SFP+ transceivers installed in EX4500 switches support digital optical monitoring (DOM): You can view the diagnostic details for these transceivers by issuing the operational mode CLI command show interfaces diagnostics optics.

    Note

    The transceivers support DOM even if they are installed in uplink module ports configured as Virtual Chassis ports.

  • EX4550—Uplink module ports on EX4550 switches support SFP, SFP+, and QSFP+ transceivers. You can find the list of transceivers supported on EX4550 switches and information about those transceivers at the Hardware Compatibility Tool page for EX4550.

    The SFP, SFP+, and QSFP+ transceivers installed in EX4550 switches support digital optical monitoring (DOM): You can view the diagnostic details for these transceivers by issuing the operational mode CLI command show interfaces diagnostics optics.

    Note

    The transceivers support DOM even if they are installed in the expansion module ports or SFP+ network ports configured as Virtual Chassis ports (VCPs).

  • EX4600—The quad small form-factor pluggable plus (QSFP+) ports in EX4600 switches support QSFP+ transceivers, QSFP+ direct-attach copper (DAC) cables, and DAC breakout cables (DACBO). Each QSFP+ port on an EX4600 switch can be configured to operate as 10-Gigabit Ethernet interface by using a breakout cable or as a single 40-Gigabit Ethernet interface. The ports on an EX4600 switch are disabled by default. You enable a port through the CLI. The 24 downlink or access ports of the EX4600 switch are 10-Gigabit Ethernet. You can find the list of transceivers supported on EX4600 switches and information about those transceivers at the Hardware Compatibility Tool page for EX4600.

  • EX6200—Uplink ports on the Switch Fabric and Routing Engine (SRE) module and line cards in EX6200 switches support SFP and SFP+ transceivers. You can find the list of transceivers supported on EX6200 switches and information about those transceivers at the Hardware Compatibility Tool page for EX6200.

    The Gigabit Ethernet SFP and SFP+ transceivers installed in EX6200 switches support digital optical monitoring (DOM). You can view the diagnostic details for these transceivers by issuing the operational mode CLI command show interfaces diagnostics optics.

  • EX8200—The line cards on EX8200 switches support SFP and SFP+ transceivers.

    The Gigabit Ethernet SFP and SFP+ transceivers installed in EX8200 switches support digital optical monitoring (DOM): You can view the diagnostic details for these transceivers by issuing the operational mode CLI command show interfaces diagnostics optics.

  • EX9200—The line cards in EX9200 switches support 1-gigabit Ethernet small form-factor pluggable (SFP), 1-gigabit Fast Ethernet SFP, 10-gigabit small form-factor pluggable plus (SFP+), 40-gigabit quad small form-factor pluggable plus (QSFP+), and 100-gigabit C form-factor pluggable (CFP) transceivers.

    The Gigabit Ethernet SFP, SFP+, and QSFP+ transceivers and the 100GBASE-LR4 CFP transceivers installed in EX9200 switches support digital optical monitoring (DOM): You can view the diagnostic details for these transceivers by issuing the operational mode CLI command show interfaces diagnostics optics.