Navigation
Displaying the SIB Environmental Status
Purpose
To display the SIB environmental status.
Action
To display the SIB environmental information, use the following command:
user@host>show chassis environment
Sample Output
T640@host>show chassis environment
Class Item Status Measurement Temp PEM 0 Absent PEM 1 OK 32 degrees C / 89 degrees F SCG 0 OK 37 degrees C / 98 degrees F SCG 1 Absent Routing Engine 0 OK 35 degrees C / 95 degrees F Routing Engine 1 Absent CB 0 OK 36 degrees C / 96 degrees F SIB 0 OK 44 degrees C / 111 degrees F SIB 1 OK 50 degrees C / 122 degrees F SIB 2 OK 50 degrees C / 122 degrees F SIB 3 OK 50 degrees C / 122 degrees F SIB 4 OK 52 degrees C / 125 degrees F [...Output truncated...]
Meaning
The command output displays each component installed in the router, including the operating status and temperature.
If there is a problem with the SIB status, you can display more detailed environmental information with the following command:
user@host>show chassis environment sib
user@host> show chassis environment sib SIB 0 status: State Spare Temperature 44 degrees C / 111 degrees F Power: GROUND 0 mV 1.8 V 1807 mV 2.5 V 2478 mV 3.3 V 3308 mV 1.8 V bias 1797 mV 3.3 V bias 3284 mV 5.0 V bias 5018 mV 8.0 V bias 7440 mV SIB 1 status: State Online Temperature 50 degrees C / 122 degrees F Power: GROUND 0 mV 1.8 V 1814 mV 2.5 V 2485 mV 3.3 V 3321 mV 1.8 V bias 1794 mV 3.3 V bias 3313 mV 5.0 V bias 5028 mV 8.0 V bias 7553 mV SIB 2 status: [...Output truncated...] SIB 3 status: [...Output truncated...] SIB 4 status: [...Output truncated...]
The command output displays the SIB slot, status, and temperature of the air flowing past the SPP card and the power supply voltages.
You can display the environmental status of a particular SIB with the following command:
user@host>show chassis environment sib slot