[ Contents] [ Prev] [ Next] [ Index] [ Report an Error]

ack-number

Syntax

ack-number {
match (equal | greater-than | less-than | not-equal);
value acknowledgement-number ;
}

Hierarchy Level

[edit security idp custom-attack attack-name attack-type signature protocol tcp]

Release Information

Statement introduced in Release 9.3 of JUNOS software.

Description

Specify the ACK number of the packet. This number identifies the next sequence number; the ACK flag must be set to activate this field.

This statement is supported on SRX-series devices.

Options

match (equal | greater-than | less-than | not-equal)—Match an operand.

value acknowledgement-number —Match the ACK number of the packet.

Range: 0 through 4294967295

Usage Guidelines

For configuration instructions and examples, see the JUNOS Software Security Configuration Guide.

Required Privilege Level

security—To view this statement in the configuration.

security-control—To add this statement to the configuration.


[ Contents] [ Prev] [ Next] [ Index] [ Report an Error]