[ Contents] [ Prev] [ Next] [ Index] [ Report an Error]

start-log

Syntax

start-log value ;

Hierarchy Level

[edit security idp sensor-configuration log suppression]

Release Information

Statement introduced in Release 9.2 of JUNOS software.

Description

Specify how many instances of a specific event must occur before log suppression begins.

This statement is supported on SRX-series devices.

Options

value —Log suppression begins after how many occurrences.

Range: 1 through 128
Default: 1

Usage Guidelines

For configuration instructions and examples, see the JUNOS Software Security Configuration Guide.

Required Privilege Level

security—To view this statement in the configuration.

security-control—To add this statement to the configuration.


[ Contents] [ Prev] [ Next] [ Index] [ Report an Error]