weight

Syntax

weight number ;

Hierarchy Level

[edit chassis cluster redundancy-group group-number interface-monitor interface ]

Release Information

Statement introduced in Release 9.0 of JUNOS software.

Description

Specify the relative importance of the interface to the operation of the redundancy group. The failure of an interface with a greater weight brings the group closer to failover. Every monitored interface is assigned a weight. If an interface fails, the weight of the interface is deducted from the threshold of its redundancy group. Every redundancy group has a threshold of 255. If the threshold reaches 0, a failover is triggered. Failover is triggered even if the redundancy group is in manual failover mode and preemption is not enabled.

This statement is supported on J-series and SRX-series devices.

Options

number —Weight assigned to the interface. A higher weight value indicates a greater importance.

Range: 0 through 255

Usage Guidelines

For configuration instructions and examples, see the JUNOS Software Security Configuration Guide.

Required Privilege Level

interface—To view this statement in the configuration.

interface-control—To add this statement to the configuration.