- weight
number ;
- [edit chassis cluster redundancy-group
group-number interface-monitor interface ]
Statement introduced in Release 9.0 of JUNOS software.
Specify the relative importance of the interface to the operation of the redundancy group. The failure of an interface with a greater weight brings the group closer to failover. Every monitored interface is assigned a weight. If an interface fails, the weight of the interface is deducted from the threshold of its redundancy group. Every redundancy group has a threshold of 255. If the threshold reaches 0, a failover is triggered. Failover is triggered even if the redundancy group is in manual failover mode and preemption is not enabled.
This statement is supported on J-series and SRX-series devices.
number —Weight assigned to the interface. A higher weight value indicates a greater importance.
For configuration instructions and examples, see the JUNOS Software Security Configuration Guide.
interface—To view this statement in the configuration.
interface-control—To add this statement to the configuration.