Verifying the Microsoft RPC ALG Tables
Purpose
To verify the Microsoft RPC ALG, display the Microsoft Universal Unique IDentifier to Object ID (UUID-to-OID) mapping table. The Microsoft RPC ALG monitors packets on TCP port 135.
Action
From the CLI, enter the show security alg msrpc object-id-map command.
user@host> show security
alg msrpc object-id-map
UUID OID 1be617c0-31a5-11cf-a7d8-00805f48a135 0x80000020 e3514235-4b06-11d1-ab04-00c04fc2dcd2 0x80000002 67df7c70-0f04-11ce-b13f-00aa003bac6c 0x80000014
Related Topics
- JUNOS Software Feature Support Reference for SRX Series and J Series Devices
- Enabling Microsoft RPC ALGs (J-Web Procedure)
- Enabling Microsoft RPC ALGs (CLI Procedure)
- Customizing Microsoft RPC Applications (CLI Procedure)