Software release
|
|
Description
|
|
Hardware features
|
|
Software features
|
SONET/SDH framing
Link aggregation
Alarm and event counting and detection
Dual-router automatic protection switching (APS)
Multiprotocol Label Switching (MPLS) fast reroute
Encapsulations:
High-Level Data Link Control (HDLC)
Frame Relay
Circuit cross-connect (CCC)
Translational cross-connect (TCC)
Point-to-Point Protocol (PPP)
|
Cables and connectors
|
Tip: You
can use the Hardware
Compatibility Tool to find information about the pluggable
transceivers supported on your Juniper Networks device.
The list of supported transceivers for the MX Series is located
at https://pathfinder.juniper.net/hct/category/#catKey=100001&modelType;=All&pf;=MX+Series.
Very short reach (VSR 1): 12-ribbon multimode fiber with
MTP connector (Rx and Tx)
Fiber-optic 10-gigabit small form-factor pluggable (XFP)
transceivers: 10GBASE-S very short reach (VSR-1) (model number: XFP-10G-S)
Note: To extend the life of the laser, when a PIC is not being
actively used with any valid links, take the PIC offline until you
are ready to establish a link to another device. For information about
taking a PIC offline, see the request chassis pic offline command in the CLI Explorer.
|
LEDs
|
One tricolor LED per port:
Off—Not enabled
Green—Online with no alarms or failures
Yellow—Online with alarms for remote failures
Red—Active with a local alarm; router has detected
a failure
|
Alarms, errors, and events
|
SONET alarms:
Alarm indication signal—line (AIS-L)
Alarm indication signal—path (AIS-P)
Bit error rate—signal degrade (BERR-SD)
Bit error rate—signal fail (BERR-SF)
Bit interleaved parity (BIP) error B1, B2, B3
Far-end bit error: remote error indication—line
(REI-L), far-end line coding violations (CV-LFE)
Far-end bit error: remote error indication—path
(REI-P), far-end path coding violations (CV-PFE)
Loss of frame (LOF)
Loss of pointer (LOP-P)
Loss of signal (LOS)
Payload label mismatch (PLM-P)
Payload unequipped (unequipped STS at path level) (UNEQ-P)
Remote defect indication—line (RDI-L)
Remote defect indication—path (RDI-P)
SDH alarms:
Administrative unit alarm indication signal (AU-AIS)
Bit error rate signal degrade (BERR-SD)
Bit error rate signal fail (BERR-SF)
Bit interleaved parity (BIP) error B1, B2, B3
Higher order path—payload label mismatch (HP-PLM)
Higher order path—loss of pointer (HP-LOP)
Higher order path—remote defect indication (HP-RDI)
Higher order path—unequipped (HP-UNEQ)
Loss of frame (LOF)
Loss of signal (LOS)
Multiplex section—alarm indication signal (MS-AIS)
Multiplex section—remote defect indication (MS-RDI)
Multiplex section—remote error indication (MS-REI)
Error detection:
Errored seconds (ES-S, ES-L, ES-P)
Far-end errored seconds (ES-LFE, ES-PFE)
Far-end severely errored seconds (SES-LFE, SES-PFE)
Far-end unavailable seconds (UAS-LFE, UAS-PFE)
Severely errored framing (SEF)
Severely errored framing seconds (SEFS-S)
Severely errored seconds (SES-S, SES-L, SES-P)