Installing the MX2010 Air Filter
To install the lower air filter—MX2010-FLTR-KIT-S:
- Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
- Ensure that the air filter is right side up.
- Open the fan tray and air filter access door, located at the bottom of the chassis.
- Grasp the handle on the air filter and insert into the chassis until it stops (see Figure 1).
- Close the access door and tighten the two captive screws to secure.
- Lower the cable manager back into position, and rearrange the cables in the cable manager.
To install the card-cage cable manager air filter—MX2010-MID-FLTR-PNL-S:
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
Move the cables from the card-cage cable manager, if necessary.
Loosen the two captive screws located on the front of the card-cage cable manager door, and open.
CAUTION:Do not run the router for more than 2 minutes without the air filter in place.
Grasp the air filter, and slide the bottom of the air filter into the channel of the access door, (see Figure 2).
Figure 2: Installing the Card-Cage Cable Manager Air FilterPush the air filter in place, close the door, and tighten the two captive screws.
Replace the cables in the card-cage cable manager, if necessary.
To install the PSM air filter—MX2000-FLTR-PWR:
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
Ensure that the air filter is right side up.
Grasp the PSM air filter and insert into the chassis until it stops, (see Figure 3).
Tighten the two captive screws to secure.
Note:The AC–powered MX2010 router has the same air filter.
To install the PSM air filter—MX2000-FLTR-PWR for chassis with 240 V China power supplies and universal (HVAC/HVDC) power supplies:
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to one of the ESD points on the chassis.
Unscrew the mechanical interlock bracket from the PDM (see Figure 4 and Figure 5).
Figure 4: Removing the Bracket from the 240 V China PDMFigure 5: Removing the Bracket from the Universal (HVAC/HVDC) PDMEnsure that the air filter is right side up.
Grasp the PSM air filter and insert into the chassis until it stops, (see Figure 6).
Tighten the two captive screws to secure.
Figure 6: Installing the PSM FilterInstall the mechanical interlock bracket and tighten the screws. See Figure 7 and Figure 8.
Figure 7: Installing the Bracket (with 240 V China PSM Installed)Figure 8: Installing the Mechanical Interlock Bracket (with Universal HVAC/HVDC PSM Installed)