Maintaining the MX2020 Host Subsystem
Maintaining the MX2020 Routing Engines
Purpose
Each host subsystem comprises a Control Board and Routing Engine (CB-RE) functioning together.
To maintain the host subsystem, check the LEDs (RE0 and RE1) on the craft interface. For more information about the LEDs and the display, see MX2020 Craft Interface Description.
Even though the Routing Engine is combined with a Control Board (CB-RE), separate LEDs on the craft interface show the status of the routing engines, and separate LEDs show the status of the Control Board.
For optimum router performance, verify the condition of the Routing Engines and the CB-REs.
Action
On a regular basis:
Check the host subsystem LEDs on the craft interface. For more information about the LEDs, and the display, see MX2020 Craft Interface Description. During normal operations:
Note:Even though the Routing Engine is combined with a Control Board (CB-RE), separate LEDs on the craft interface show the status of the routing engines, and separate LEDs show the status of the Control Board.
The green host subsystem ONLINE LED on the craft interface is lit.
The red host subsystem OFFLINE LED on the craft interface is not lit.
Check the LEDs on the Routing Engine portion of the CB-RE faceplate. During normal operations, the ONLINE LED is lit steadily green.
Issue the
show chassis routing-engine
command to check the status of the Routing Engines. The output is similar to the following:
user@host> show chassis routing-engine Routing Engine status: Slot 0: Current state Master Election priority Master (default) Temperature 36 degrees C / 96 degrees F CPU temperature 31 degrees C / 87 degrees F DRAM 16351 MB (16384 MB installed) Memory utilization 7 percent CPU utilization: User 0 percent Background 0 percent Kernel 4 percent Interrupt 1 percent Idle 95 percent Model RE-S-1800x4 Serial ID 9009099715 Start time 2012-12-02 23:37:00 PST Uptime 10 hours, 16 minutes, 36 seconds Last reboot reason Router rebooted after a normal shutdown. Load averages: 1 minute 5 minute 15 minute 0.00 0.00 0.00 Routing Engine status: Slot 1: Current state Backup Election priority Backup (default) Temperature 28 degrees C / 82 degrees F CPU temperature 26 degrees C / 78 degrees F DRAM 3313 Memory utilization 22 percent CPU utilization: User 0 percent Background 0 percent Kernel 0 percent Interrupt 0 percent Idle 100 percent Model RE-S-1800x4 Serial ID 9009099711 Start time 2012-11-30 15:56:39 PST Uptime 2 days, 17 hours, 56 minutes, 36 seconds Last reboot reason Router rebooted after a normal shutdown. Load averages: 1 minute 5 minute 15 minute 0.00 0.00 0.00
For further description of the output from the command, see the Junos OS System Basics and Services Command Reference.
See Also
Maintaining the MX2020 Control Boards
Purpose
For optimum router performance, verify the condition of the Control Board and Routing Engine (CB-RE).
Action
On a regular basis:
Check the host subsystem LEDs on the craft interface. For more information about the LEDs and the display, see MX2000 Switch Fabric Board LED.
During normal operations:
The green host subsystem ONLINE LED on the craft interface is lit.
The red host subsystem OFFLINE LED on the craft interface is not lit.
Check the LEDs on the control board portion of the CB-RE faceplate.
During normal operations:
The green OK LED on the CB-RE faceplate is lit.
The red FAIL LED on the CB-RE faceplate is not lit.
Issue the
show chassis environment cb
command to check the status of the CB-REs. The output is similar to the following:user@host> show chassis environment cb CB 0 status: State Online Master IntakeA-Zone0 Temperature 25 degrees C / 77 degrees F IntakeB-Zone1 Temperature 29 degrees C / 84 degrees F IntakeC-Zone0 Temperature 28 degrees C / 82 degrees F ExhaustA-Zone0 Temperature 26 degrees C / 78 degrees F ExhaustB-Zone1 Temperature 28 degrees C / 82 degrees F TCBC-Zone0 Temperature 32 degrees C / 89 degrees F Power 1 1.0 V 1008 mV 1.2 V 1208 mV 1.8 V 1801 mV 2.5 V 2526 mV 3.3 V 3312 mV 5.0 V 5020 mV 5.0 V RE 4995 mV 12.0 V 12123 mV 12.0 V RE 12007 mV Bus Revision 100 FPGA Revision 271 CB 1 status: State Online Standby IntakeA-Zone0 Temperature 30 degrees C / 86 degrees F IntakeB-Zone1 Temperature 25 degrees C / 77 degrees F IntakeC-Zone0 Temperature 39 degrees C / 102 degrees F ExhaustA-Zone0 Temperature 33 degrees C / 91 degrees F ExhaustB-Zone1 Temperature 28 degrees C / 82 degrees F TCBC-Zone0 Temperature 31 degrees C / 87 degrees F Power 1 1.0 V 1015 mV 1.2 V 1211 mV 1.8 V 1814 mV 2.5 V 2545 mV 3.3 V 3345 mV 5.0 V 5066 mV 5.0 V RE 5020 mV 12.0 V 12104 mV 12.0 V RE 12046 mV Bus Revision 100 FPGA Revision 0
For further description of the output from the command, see the Junos OS System Basics and Services Command Reference.