- play_arrow Fast Track: Initial Installation
- play_arrow Overview
- MX480 Router Description
- MX480 Chassis
- MX480 Cooling System
- MX480 Air Deflector Kits
- MX480 Power System Description
- MX480 AC Power System
- MX480 DC Power System
- MX480 Host Subsystem
- MX480 Interface Modules—DPCs
- MX480 Interface Modules—FPCs and PICs
- MX480 Interface Modules—MPCs and MICs
- Services Processing Card—MX-SPC3 Services Card
- MX-Series Switch Control Board (SCB) Description
- play_arrow Site Planning, Preparation, and Specifications
- play_arrow Initial Installation and Configuration
- play_arrow Maintaining Components
- Maintaining MX480 Components
- Maintaining MX480 Cooling System Components
- Maintaining MX480 Host Subsystem Components
- Maintaining MX480 Interface Modules
- Maintaining MX-SPC3 Services Card
- Maintaining MX480 Power System Components
- Maintaining MX480 SFP and XFP Transceivers
- Maintaining MX480 Switch Control Boards
- play_arrow Troubleshooting Hardware
- play_arrow Contacting Customer Support and Returning the Chassis or Components
Prevention of Electrostatic Discharge Damage
Device components that are shipped in antistatic bags are sensitive to damage from static electricity. Some components can be impaired by voltages as low as 30 V. You can easily generate potentially damaging static voltages whenever you handle plastic or foam packing material or if you move components across plastic or carpets. Observe the following guidelines to minimize the potential for electrostatic discharge (ESD) damage, which can cause intermittent or complete component failures:
Always use an ESD wrist strap when you are handling components that are subject to ESD damage, and make sure that it is in direct contact with your skin.
If a grounding strap is not available, hold the component in its antistatic bag (see Figure 1) in one hand and touch the exposed, bare metal of the device with the other hand immediately before inserting the component into the device.
Warning:For safety, periodically check the resistance value of the ESD grounding strap. The measurement must be in the range 1 through 10 Mohms.
Avertissement Par mesure de sécurité, vérifiez régulièrement la résistance du bracelet antistatique. Cette valeur doit être comprise entre 1 et 10 mégohms (Mohms).
When handling any component that is subject to ESD damage and that is removed from the device, make sure the equipment end of your ESD wrist strap is attached to the ESD point on the chassis.
If no grounding strap is available, touch the exposed, bare metal of the device to ground yourself before handling the component.
Avoid contact between the component that is subject to ESD damage and your clothing. ESD voltages emitted from clothing can damage components.
When removing or installing a component that is subject to ESD damage, always place it component-side up on an antistatic surface, in an antistatic card rack, or in an antistatic bag (see Figure 1). If you are returning a component, place it in an antistatic bag before packing it.
Figure 1: Placing a Component into an Antistatic Bag
ANSI/TIA/EIA-568 cables such as Category 5e and Category 6 can get electrostatically charged. To dissipate this charge, always ground the cables to a suitable and safe earth ground before connecting them to the system.
Attention Les câbles ANSI/TIA/EIA-568, par exemple Cat 5e et Cat 6, peuvent emmagasiner des charges électrostatiques. Pour évacuer ces charges, reliez toujours les câbles à une prise de terre adaptée avant de les raccorder au système.