MX960 AC Power Supply LEDs
Each AC power supply faceplate contains three LEDs that indicate the status of the power supply (see Table 1and Table 2 ). The power supply status is also reflected in two LEDs on the craft interface In addition, a power supply failure triggers the red alarm LED on the craft interface.
Label |
Color |
State |
Description |
---|---|---|---|
AC OK |
Green |
Off |
AC power applied to power supply is not within the normal operating range. |
On |
AC power applied to power supply is within the normal operating range. |
||
DC OK |
Green |
Off |
DC power outputs generated by the power supply are not within the normal operating ranges. |
On |
DC power outputs generated by the power supply are within the normal operating ranges. |
||
PS FAIL |
Red |
Off |
Power supply is functioning normally. |
On |
Power supply is not functioning normally. Check AC OK and DC OK LEDs for more information. |
Each high-capacity second-generation AC power supply faceplate contains four LEDs that indicate the status of the power supply (see Figure 1 and Table 2).
Label |
Color |
State |
Description |
---|---|---|---|
INP0 OK |
Green |
Off |
AC power applied to power supply is not within the normal operating range. |
On |
AC power applied to power supply is within the normal operating range. |
||
INP1 OK |
Green |
Off |
AC power applied to power supply is not within the normal operating range. |
On |
AC power applied to power supply is within the normal operating range. |
||
DC OK |
Green |
Off |
DC power outputs generated by the power supply are not within the normal operating ranges. |
On |
DC power outputs generated by the power supply are within the normal operating ranges. |
||
PS FAIL |
Red |
Off |
Power supply is functioning normally. |
On |
Power supply is not functioning normally. Check AC OK and DC OK LEDs for more information. |