Problem

Description

The FPCs are not functioning normally.

Solution

  • Monitor the green LED labeled OK above the FPC on the craft interface as soon as an FPC is seated in an operating router.

    The Routing Engine downloads the FPC software to it under two conditions: the FPC is present when the Routing Engine boots Junos OS, and the FPC is installed and requested online through the CLI or push button on the front panel. The FPC then runs diagnostics, during which the OK LED blinks. When the FPC is online and functioning normally, the OK LED lights green steadily.

  • Make sure the FPC is properly seated in the midplane. Check that each ejector handle has been turned clockwise and is tight.

  • Check the OK/FAIL LED on the FPC and OK and FAIL FPC LEDs on the craft interface. When the FPC is online and functioning normally, the OK LED lights green steadily.

  • Issue the show chassis fpc command to check the status of installed FPCs. As shown in the sample output, the value Online in the column labeled State indicates that the FPC is functioning normally:

    content_copy zoom_out_map
    user@host> show chassis fpc
                  Temp  CPU Utilization (%)   Memory    Utilization (%)
    Slot State    (C)  Total  Interrupt      DRAM (MB) Heap     Buffer
      0  Online   24      3          0       1024       13         21
      1  Empty
      2  Online   41      9          0       1024       15         57
      3  Online   43      5          0       1024       16         57
      4  Online   43     11          0       1024       16         57
      5  Online   41      9          0       1024       15         57
      6  Online   43      5          0       1024       16         57
      7  Empty
      8  Empty
      9  Empty
      10 Online   24      3          0       1024       13         21
      11 Empty           
     
    Note:

    The show chassis fpc command displays the status of the FPCs.

    For more detailed output, add the detail option. The following example does not specify a slot number, which is optional:

    content_copy zoom_out_map
    user@host> show chassis fpc detail
    Slot 0 information:
      State                                 Online    
      Temperature                        24 degrees C / 75 degrees F
      Total CPU DRAM                   1024 MB
      Total RLDRAM                      128 MB
      Total DDR DRAM                   2048 MB
      Start time:                           2008-12-11 16:53:24 PST
      Uptime:                               15 hours, 2 minutes, 47 seconds
    Slot 2 information:
      State                                 Online    
      Temperature                        29 degrees C / 84 degrees F
      Total CPU DRAM                   1024 MB
      Total RLDRAM                      256 MB
      Total DDR DRAM                   4096 MB
      Start time:                           2008-12-11 16:53:18 PST
      Uptime:                               15 hours, 2 minutes, 53 seconds
    Slot 3 information:
      State                                 Online    
      Temperature                        29 degrees C / 84 degrees F
      Total CPU DRAM                   1024 MB
      Total RLDRAM                      256 MB
      Total DDR DRAM                   4096 MB
      Start time:                           2008-12-11 16:53:18 PST
      Uptime:                               15 hours, 2 minutes, 53 seconds
    Slot 4 information:
      State                                 Online    
      Temperature                        29 degrees C / 84 degrees F
      Total CPU DRAM                   1024 MB
      Total RLDRAM                      256 MB
      Total DDR DRAM                   4096 MB
      Start time:                           2008-12-11 16:53:18 PST
      Uptime:                               15 hours, 2 minutes, 53 seconds
    Slot 5 information:
      State                                 Online    
      Temperature                        29 degrees C / 84 degrees F
      Total CPU DRAM                   1024 MB
      Total RLDRAM                      256 MB
      Total DDR DRAM                   4096 MB
      Start time:                           2008-12-11 16:53:22 PST
      Uptime:                               15 hours, 2 minutes, 49 seconds
    Slot 6 information:
      State                                 Online    
      Temperature                        29 degrees C / 84 degrees F
      Total CPU DRAM                   1024 MB
      Total RLDRAM                      256 MB
      Total DDR DRAM                   4096 MB
      Start time:                           2008-12-11 16:53:18 PST
      Uptime:                               15 hours, 2 minutes, 53 seconds
    Slot 10 information:
      State                                 Online    
      Temperature                        24 degrees C / 75 degrees F
      Total CPU DRAM                   1024 MB
      Total RLDRAM                      128 MB
      Total DDR DRAM                   2048 MB
      Start time:                           2008-12-11 16:53:24 PST
      Uptime:                               15 hours, 2 minutes, 47 seconds
    

    For further description of the output from the commands, see the Junos OS Administration Library for Routing Devices.