Help us improve your experience.

Let us know what you think.

Do you have time for a two-minute survey?

 
 

10-Gigabit Ethernet LAN/WAN OTN PIC with SFP+ (PTX Series)

Software Release

  • PTX3000: Junos OS Release 13.2R2 and later

  • PTX5000: Junos OS Release 12.3R2 and later, Junos OS Release 13.2R1 and later

    Note:

    PTX5000 does not support Junos OS Release 13.1.

For information about which FPCs support these PICs, see PTX Series PIC/FPC Compatibility.

Hardware Features

  • Twenty-four 10-Gigabit Ethernet SFP+ ports

  • Model number: P1-PTX-24-10G-W-SFPP

  • Name in the CLI: 24x 10GE(LWO) SFP+

  • Power requirements: 2.67 A @ –48 V (128 W)

  • High-performance throughput: LAN-PHY mode at 10.3125 Gbps and WAN-PHY mode at 9.95 Gbps

    Configurable modes:

    • LAN-PHY

    • WAN-PHY

    • OTN

  • Full-duplex mode

  • Large maximum transmission units (MTUs): up to 9500 bytes

Software Features

Table 1 shows the first supported Junos OS release for each software feature.

Table 1: Software Features Supported

Software Feature

PTX3000 First Supported Junos OS Release

PTX5000 First Supported Junos OS Release

Flexible-ethernet-services encapsulation

13.2R2

12.3R2

13.2R1

Flexible VLAN tagging

13.2R2

12.3R2

13.2R1

IFINFO / IFMON

13.2R2

12.3R2

13.2R1

IEEE 802.1 ag OAM

13.2R2

12.3R2

13.2R1

IEEE 802.3 ah OAM

13.2R2

12.3R2

13.2R1

IEEE 802.3ad link aggregation

13.2R2

12.3R2

13.2R1

Interrupt-driven link-down detection for MPLS FRR

13.2R2

12.3R2

13.2R1

MAC accounting per logical interface for source addresses

13.2R2

12.3R2

13.2R1

MAC filter per port for destination addresses and source addresses

13.2R2

12.3R2

13.2R1

MAC filter per logical interface for source addresses

13.2R2

12.3R2

13.2R1

SNMP

13.2R2

12.3R2

13.2R1

Up to 8000 logical interfaces shared across all ports on a single Packet Forwarding Engine

13.2R2

12.3R2

13.2R1

Compliant with ITU G.709, G.975.1 I.4 and G.975.1 I.7

14.2R1

14.2R1

Provides a transport interface and state model (GR-1093)

14.2R1

14.2R1

OTN mapping modes:

  • 10G LAN-PHY over OTU2e/OTU1e

  • 10G WAN-PHY over OTU2

14.2R1

14.2R1

Performance monitoring such as alarms, threshold crossing alerts, OTU/ODU error seconds and pre-FEC statistics

14.2R1

14.2R1

SNMP management of the PIC based on RFC 3591, Managed Objects for the Optical Interface Type

  • Set functionality

  • Juniper Networks Black-Link MIB

  • IFOTN MIB

  • Optics MIB

  • FRU MIB

14.2R1

14.2R1

Cables and Connectors

Tip:

You can use the Hardware Compatibility Tool to find information about the pluggable transceivers supported on your Juniper Networks device.

This PIC supports the following transceivers:

  • 10GBASE-SR (model number: SFPP-10GE-SR)

  • 10GBASE-LR (model number: SFPP-10GE-LR)

  • 10GBASE-ER (model number: SFPP-10GE-ER)

  • 10GBASE-ZR (model number: SFPP-10GE-ZR)

  • 10GBASE-ZR (model number: SFPP-10G-CT50-ZR)

    • Supported in Junos OS Release 13.2R3, 13.3R2, 14.1R2, and later

    • Supports LAN-PHY and WAN-PHY modes, and OTN rates

    • Tunable by configuring the wavelength statement at the [edit interfaces interface-name optics-options] hierarchy level (see wavelength)

  • 10GBASE-ZR (model number: SFPP-10G-DT-ZRC2)

    • Supported in Junos OS Release 13.2R5, 13.3R3, 14.1R2, and 14.2, and later

    • Supports LAN-PHY and WAN-PHY modes

    • Supports OTN rates of 10.70932 Gbps (OTU2) and 11.0957 Gbps (OTU2e)

    • Tunable by configuring the wavelength statement at the [edit interfaces interface-name optics-options] hierarchy level (see wavelength)

    • NEBS compliant

LEDs

The STATUS LED is located above the ONLINE OFFLINE button. The LINK and ACT LEDs are located next to each port. Table 2 describes the functions of these LEDs.

Table 2: 10-Gigabit Ethernet LAN/WAN OTN PIC with SFP+ LEDs

Label

Color

State

Description

STATUS

Green

On steadily

PIC is operating normally.

Yellow

On steadily

PIC is initializing.

Red

On steadily

PIC has an error or failure.

Off

PIC is offline and safe to remove from the router.

LINK (for each port)

Green

On steadily

Port is on with no alarms or errors.

Red

On steadily

Port has detected an alarm or error.

Off

Port is off.

ACT (for each port)

Green

Flashing

Link has activity.

Off

No activity.

Alarms, Errors, and Events

Chassis and PIC:

  • PIC (FRU) inserted or removed

  • PIC (FRU) Admin InService/OutOfService, Oper Unequipped/Init/Normal/Mismatch/Fault/Upgrade

  • Mismatch equipment

  • Temperature alarm

  • Fan alarm

Port (interface):

  • Interface Admin InService/OutOfService/ServiceMA/OutOfServiceMA, Oper Init/Normal/Fault/Degraded

OTN (optical transport network):

  • LOS (loss of signal)

  • LOF (loss of frame)

  • LOM (loss of multiframe)

  • SSF (server signal failure)

  • TSF (trail signal fail)

OTU (optical channel transport unit):

  • OTU-FEC-DEG (forward error correction degraded)

  • OTU-FEC-EXE (excessive errors, FEC_FAIL from the transponder)

  • OTU-AIS (alarm indication signal or all ones signal)

  • OTU-BDI (backward defect identification)

  • OTU-IAE (incoming alignment error)

  • OTU-BIAE (backward incoming alignment error)

  • OTU-TTIM (destination access point identifier [DAPI], source access point identifier [SAPI], or both mismatch from expected to received)

  • OTU-SD (signal degrade)

  • OTU-SF (signal fail)

ODU (optical channel data unit):

  • CSF (client signal failure)

  • ODU-LCK (ODU lock triggers for PM [path monitoring] and TCM levels 1 through 6)

  • ODU-AIS (alarm indication signal or all ones signal)

  • ODU-OCI (open connection error)

  • ODU-BDI (backward defect indication)

  • ODU-IAE (incoming alignment error)

  • ODU-DAPI-TTIM (DAPI or DAPI/SAPI mismatch from expected to receive)

  • ODU-SAPI-TTIM (SAPI or DAPI/SAPI mismatch from expected to receive)

  • ODU-BEI (backward error indication)

  • ODU-SSF (server signal fail)

  • ODU-TSF (trail signal fail)

  • ODU-SD (signal degrade)

  • ODU-SF (signal fail)

OPU (optical channel payload):

  • OPU-PTM (payload type mismatch)

Card-related status:

  • Transceiver temperature high alarm

  • Transceiver temperature high warning

  • Transceiver temperature low alarm

  • Transceiver temperature low warning

  • Transceiver voltage high alarm

  • Transceiver voltage high warning

  • Transceiver voltage low alarm

  • Transceiver voltage low warning

  • Transceiver temperature monitor A/D value

  • Transceiver power supply monitor A/D value (voltage)

  • Transceiver minimum temperature over PM interval

  • Transceiver average temperature over PM interval

  • Transceiver maximum temperature over PM interval

Network lane transmit–related status:

  • TX laser current bias high alarm

  • TX laser current bias high warning

  • TX laser current bias low alarm

  • TX laser current bias low warning

  • TX current laser output power

  • TX minimum laser output power over PM interval

  • TX average laser output power over PM interval

  • TX maximum laser output power over PM interval

  • TX laser bias current value

  • TX output optical power high alarm

  • TX output optical power high warning

  • TX output optical power low alarm

  • TX output optical power low warning

  • TX minimum laser bias current over PM interval

  • TX average laser bias current over PM interval

  • TX maximum laser bias current over PM interval

Network lane receive–related status:

  • RX input optical power high alarm

  • RX input optical power high warning

  • RX input optical power low alarm

  • RX input optical power low warning

  • RX LOS

  • RX Laser wavelength unlocked fault

  • RX laser TEC fault

  • RX input optical power

  • RX minimum input optical power over PM interval

  • RX average input optical power over PM interval

  • RX maximum input optical power over PM interval