- play_arrow Fast Track: Initial Installation
- play_arrow Overview
- play_arrow Site Planning, Preparation, and Specifications
- play_arrow Initial Installation and Configuration
- play_arrow Contacting Customer Support and Returning the Chassis or Components
- play_arrow Safety and Compliance Information
- Definitions of Safety Warning Levels
- General Safety Guidelines and Warnings
- Restricted Access Warning
- Qualified Personnel Warning
- Prevention of Electrostatic Discharge Damage
- Fire Safety Requirements
- Laser and LED Safety Guidelines and Warnings
- Radiation from Open Port Apertures Warning
- Maintenance and Operational Safety Guidelines and Warnings
- Action to Take After an Electrical Accident
- General Electrical Safety Guidelines and Warnings
- AC Power Electrical Safety Guidelines
- SRX380 Firewall Agency Approvals
- SRX380 Firewall EMC Requirements
Maintaining SRX380 Components
Routine Maintenance Procedures for the SRX380 Firewall
For optimum performance of the SRX380, perform the following preventive maintenance procedures regularly:
Inspect the installation site for moisture, loose wires or cables, and excessive dust.
Make sure that airflow is unobstructed around the services gateway and into the air intake vents.
Check the status LEDs on the front panel of the services gateway.
Maintaining the SRX380 Firewall Cooling System Components
The fan controller works to maintain an optimal temperature for the services gateway. If the fan controller fails, the temperature of the services gateway will exceed the maximum working temperature and the device will fail. Make sure that you maintain the recommended clearances behind the services gateway to enable the fan controller to function optimally.
Maintaining the SRX380 Firewall Power Supply
To maintain the power supplies of the services gateway:
Make sure that all power cables are arranged so that they do not obstruct access to other components of the services gateway.
Routinely check the LEDs on the power supplies at the rear of the chassis. If the LEDs are lit solid green, then the power supplies are functioning normally.
Periodically inspect the site to ensure that the power cables connected to the services gateway are securely in place and that there is no moisture accumulating near the services gateway.
Check the status of the power supplies on the device by using the
show chassis environment
orshow chassis hardware
command. The output is similar to the following:content_copy zoom_out_mapuser@host> show chassis environment Class Item Status Measurement Temp Routing Engine OK 42 degrees C / 107 degrees F Routing Engine CPU OK 59 degrees C / 138 degrees F Fans SRX380 Chassis fan 0 OK Spinning at normal speed SRX380 Chassis fan 1 OK Spinning at normal speed SRX380 Chassis fan 2 OK Spinning at normal speed Power Power Supply 0 OK Power Supply 1 Absent
content_copy zoom_out_mapuser@host> show chassis hardware Hardware inventory: Item Version Part number Serial number Description Chassis EW4519AF0040 SRX380-POE-AC Routing Engine REV 03 650-097090 EW4519AF0040 RE-SRX380-POE-AC FPC 0 FPC PIC 0 16xGE,4*SFP+ Base PIC Power Supply 0 REV 04 640-060602 1EDX933076P JPSU-600W-AC-AFO