Chassis Alarm Messages on a QFX3500 Device
Chassis alarms indicate a failure on the device or one of its components. Chassis alarms are preset and cannot be modified.
The chassis alarm message count is displayed on the LCD panel
on the front of the device. To view the chassis alarm message text
remotely, use the show chassis lcd
CLI command.
Chassis alarms on QFX3500 devices have two severity levels:
Major (red)—Indicates a critical situation on the device that has resulted from one of the conditions described in Table 1. A red alarm condition requires immediate action.
Minor (yellow or amber)—Indicates a noncritical condition on the device that, if left unchecked, might cause an interruption in service or degradation in performance. A yellow alarm condition requires monitoring or maintenance.
Table 1 describes the chassis alarm messages on QFX3500 devices.
Component |
Alarm Type |
CLI Message |
Recommended Action |
---|---|---|---|
Fans |
Major (red) |
|
The fan is missing. Install a fan. |
|
Replace the fan and report the failure to customer support. |
||
|
Check the system log for one of the following messages and report the error message to customer support:
|
||
|
Remove and check the fan for obstructions, and then reinsert the fan. If the problem persists, replace the fan. |
||
Power Supplies |
Major (red) |
|
The power supply airflow direction is the opposite of the chassis airflow direction. Replace the power supply with a power supply that supports the same airflow direction as the chassis. |
|
Check the system log for one of the following messages and report the error message to customer support:
|
||
|
Indicates a power supply problem, or the power supply is not supported on the device. Report the problem to customer support. |
||
|
Indicates a problem with the incoming AC or outgoing DC power. Replace the power supply. |
||
Minor (yellow) |
|
For information only. Indicates the device was powered on with two power supplies installed, but now one is missing. The device can continue to operate with a single power supply. If you wish to remove this alarm message, reboot the device with one power supply. |
|
|
For information only. Check the power cord connection and reconnect it if necessary. |
||
|
For information only. Indicates that an AC power supply and DC power supply have been installed in the same chassis. If you wish to remove this alarm message, reboot the device with two AC power supplies or two DC power supplies. |
||
|
For information only. Indicates the device was powered on with two power supplies installed, but one has been removed. The device can continue to operate with a single power supply. If you wish to remove this alarm message, reboot the device with one power supply. |
||
Temperature Sensors |
Major (red) |
|
Check the system log for the following message and report it to customer support:
|
|
Check environmental conditions and alarms on other devices. Ensure that environmental factors (such as hot air blowing around the equipment) are not affecting the temperature sensor. If the condition persists, the device may shut down. |
||
Minor (yellow) |
|
For information only. Check environmental conditions and alarms on other devices. Ensure that environmental factors (such as hot air blowing around the equipment) are not affecting the temperature sensor. |