Removing a Power Supply from a QFX5110
Before you remove a power supply from a QFX5110, ensure that you have taken the necessary precautions to prevent electrostatic discharge (ESD) damage (see Prevention of Electrostatic Discharge Damage).
Ensure that you have the following parts and tools available to remove a power supply from a QFX5110:
ESD grounding strap
Antistatic bag or an antistatic mat
Phillips (+) screwdriver, number 2 (DC power supply)
All QFX5110 switches, except the QFX5110-32Q-CHAS are shipped from the factory with two power supplies. Each power supply is a hot-removable and hot-insertable field-replaceable unit (FRU) when the second power supply is installed and running. You can install replacement power supplies in the two slots next to the fan modules without powering off the switch or disrupting the switching function.
Replace the power supply with a new power supply within 1 minute of removal to prevent chassis overheating.
To remove a power supply from a QFX5110 (see Figure 1):