100-Gigabit DWDM OTN PIC (PTX Series)
|
|
Software Release
PTX Series routers support the following 100-Gigabit DWDM (dense wavelength division multiplexing) OTN (optical transport network) PICs:
-
100-Gigabit DWDM OTN PIC (P1-PTX-2-100G-WDM):
-
PTX3000: Junos OS Release 13.3 and later
-
PTX5000: Junos OS Release 13.2 and later
-
For information about which FPCs support this PIC, see PTX Series PIC/FPC Compatibility.
Hardware Features
-
Model number:
-
P1-PTX-2-100G-WDM—Designed for metro, regional, or long-haul applications.
-
-
Two 100-Gigabit DWDM OTN ports
-
Power requirements: 6.48 A @ –48 V (311 W)
-
Transparent transport of two 100-Gigabit Ethernet signals with OTU4V framing
-
ITU-standard OTN performance monitoring and alarm management
-
Dual polarization-quadrature phase-shift keying (DP-QPSK) modulation and soft-decision forward error correction (SD-FEC) for long haul and metro applications
-
96 channels on C-band ITU grid with 50-GHz spacing
-
Full-duplex mode
-
Maximum transmission units (MTUs) up to 9500 bytes
-
Latency: 32 µs (TX + RX)
The 100-Gigabit DWDM OTN PIC is designed to comply with NEBS regulations on the PTX5000 router when used in typical configurations. The typical configuration for a PTX5000 router is up to eight FPCs, with one 100-Gigabit DWDM OTN PIC and one 100-Gigabit Ethernet PIC with CFP, 40-Gigabit Ethernet PIC with CFP, or 10-Gigabit Ethernet PIC with SFP+ installed in the same FPC.
The 100-Gigabit DWDM OTN PIC is designed to comply with NEBS regulations on the PTX3000 router when used in typical configurations at 40° C (104° F) at sea level. The typical configuration for a PTX3000 router is up to eight FPCs, with one 100-Gigabit DWDM OTN PIC next to each FPC in the top row only. The 100-Gigabit Ethernet PIC with CFP, 40-Gigabit Ethernet PIC with CFP, or 10-Gigabit Ethernet PIC with SFP+ are supported next to any FPC.
Software Features
100-Gigabit DWDM OTN PIC (PTX Series) shows the first supported release for each software feature.
Software Feature |
PTX3000 First Supported Junos OS Release |
PTX5000 First Supported Junos OS Release |
---|---|---|
Compliant with ITU G.709 and G.798 |
|
|
Provides a transport interface and state model (GR-1093) |
|
|
Performance monitoring such as alarms, threshold-crossing alarms, OTU/ODU error seconds and pre-FEC statistics |
|
|
SNMP management of the PIC based on RFC 3591, Managed Objects for the Optical Interface Type
|
|
|
IEEE 802.1ag OAM |
|
|
IEEE 802.3ah OAM |
|
|
IFINFO/IFMON |
|
|
IEEE 802.3ad link aggregation |
|
|
Pre-FEC BER monitoring provides interrupt-driven link-signal-degrade BER-based detection for MPLS fast reroute |
|
|
Flexible Ethernet services encapsulation |
|
|
Flexible VLAN tagging |
|
|
Source address MAC accounting per logical interface |
|
|
Source address MAC filter per port |
|
|
Source address MAC filter per logical interface |
|
|
Destination address MAC filter per port |
|
|
Up to 8000 logical interfaces shared across all ports on a single PFE |
|
|
Cables and Connectors
-
Single-mode optical fiber (ITU-T G.652)
-
Duplex LC connector (Rx and Tx)
-
Optical interface specifications
LEDs
The STATUS LED is located above the ONLINE OFFLINE button. The LINK and ACT LEDs are located next to each port. 100-Gigabit DWDM OTN PIC (PTX Series) describes the functions of these LEDs.
Label |
Color |
State |
Description |
---|---|---|---|
STATUS |
Green |
On steadily |
PIC is online with no alarms or failures. |
Yellow |
On steadily |
PIC is initializing. |
|
Red |
On steadily |
PIC is online but has errors or alarms. |
|
– |
Off |
PIC is offline or not enabled. |
|
LINK for each port: |
Green |
On steadily |
Port is online with no alarms or failures, and the link is up. |
Yellow |
Port has detected an alarm or failure. |
||
Red |
On steadily |
Port has detected a media alarm or failure. |
|
– |
Off |
Port is off or not enabled. |
|
ACT for each port |
Green |
Flashing |
Activity detected. Port is sending or receiving packets. |
– |
Off |
No packet activity detected on the port. |
Alarms, Errors, and Events
Chassis and PIC:
-
PIC (FRU) inserted or removed
-
PIC (FRU) Admin InService/OutOfService, Oper Unequipped/Init/Normal/Mismatch/Fault/Upgrade
-
Mismatch equipment
-
Temperature alarm
-
Fan alarm
Port (interface):
-
Interface Admin InService/OutOfService/ServiceMA/OutOfServiceMA, Oper Init/Normal/Fault/Degraded
OTN (optical transport network):
-
LOS (loss of signal)
-
LOF (loss of frame)
-
LOM (loss of multiframe)
-
SSF (server signal failure)
-
TSF (trail signal fail)
OTU (optical channel transport unit):
-
OTU-FEC-DEG (forward error correction degraded)
-
OTU-FEC-EXE (excessive errors, FEC_FAIL from the transponder)
-
OTU-AIS (alarm indication signal or all ones signal)
-
OTU-BDI (backward defect identification)
-
OTU-IAE (incoming alignment error)
-
OTU-BIAE (backward incoming alignment error)
-
OTU-TTIM (destination access point identifier [DAPI], source access point identifier [SAPI], or both mismatch from expected to received)
-
OTU-DEG (OTU degraded)
ODU (optical channel data unit):
-
CSF (client signal failure)
-
ODU-DM-TIMEOUT (DM timeout)
-
ODU-LCK (ODU lock triggers for path monitoring and TCM levels 1 through 6)
-
ODU-AIS (alarm indication signal or all ones signal)
-
ODU-OCI (open connection error)
-
ODU-BDI (backward defect indication)
-
ODU-DEG (ODU degraded)
-
ODU-IAE (incoming alignment error)
-
ODU-DAPI-TTIM (DAPI or DAPI/SAPI mismatch from expected to receive)
-
ODU-SAPI-TTIM (SAPI or DAPI/SAPI mismatch from expected to receive)
-
ODU-BEI (backward error indication)
-
ODU-BEI-ERR (backward error indication error)
-
ODU-BIP8-ERR (bit interleaved parity 8 error)
-
ODU-SSF (server signal fail)
-
ODU-TSF (trail signal fail)
-
ODU-SD (signal degrade)
OPU (optical channel payload):
-
OPU-PTM (payload type mismatch)
Optics:
-
TX output power
Card-related status:
-
Transceiver temperature high alarm
-
Transceiver temperature high warning
-
Transceiver temperature low alarm
-
Transceiver temperature low warning
-
Transceiver voltage high alarm
-
Transceiver voltage high warning
-
Transceiver voltage low alarm
-
Transceiver voltage low warning
-
Transceiver temperature monitor A/D value
-
Transceiver power supply monitor A/D value (voltage)
Network lane transmit–related status:
-
TX laser current bias high alarm
-
TX laser current bias high warning
-
TX laser current bias low alarm
-
TX laser current bias low warning
-
TX laser temperature high alarm
-
TX laser temperature high warning
-
TX laser temperature low alarm
-
TX laser temperature low warning
-
TX output optical power high alarm
-
TX output optical power high warning
-
TX output optical power low alarm
-
TX output optical power low warning
-
TX laser TEC fault
-
TX laser wavelength unlocked fault
-
TX modulator bias high alarm
-
TX modulator bias high warning
-
TX modulator bias low alarm
-
TX modulator bias low warning
-
TX loss of signal fault
-
TX current laser output power
-
TX minimum laser output power over a performance monitoring interval
-
TX average laser output power over a performance monitoring interval
-
TX maximum laser output power over a performance monitoring interval
Network lane receive–related status:
-
RX laser bias current high alarm
-
RX laser bias current high warning
-
RX laser bias current low alarm
-
RX laser bias current low warning
-
RX input optical power high alarm
-
RX input optical power high warning
-
RX input optical power low alarm
-
RX input optical power low warning
-
RX laser output high alarm
-
RX laser output high warning
-
RX laser output low alarm
-
RX laser output low warning
-
RX laser temperature high alarm
-
RX laser temperature high warning
-
RX laser temperature low alarm
-
RX laser temperature low warning
-
RX LOS
-
RX Laser wavelength unlocked fault
-
RX laser TEC fault
-
RX current chromatic dispersion
-
RX average chromatic dispersion over a performance monitoring interval
-
RX minimum chromatic dispersion over a performance monitoring interval
-
RX maximum chromatic dispersion over a performance monitoring interval
-
RX current Q
-
RX average Q over a performance monitoring interval
-
RX minimum Q over a performance monitoring interval
-
RX maximum Q over a performance monitoring interval
-
RX current carrier frequency offset
-
RX average carrier frequency offset over a performance monitoring interval
-
RX minimum carrier frequency offset over a performance monitoring interval
-
RX maximum carrier frequency offset over a performance monitoring interval
-
RX current SNR (signal-to-noise ratio)
-
RX average SNR
-
RX minimum SNR
-
RX maximum SNR
-
RX modem sync detect fault occurred over a performance monitoring interval
-
RX modem lock fault occurred over a performance monitoring interval
-
RX loss of alignment occurred over a performance monitoring interval
-
RX out of alignment occurred over a performance monitoring interval
-
RX deskew lock fault occurred over a performance monitoring interval
-
RX LOS occurred over a performance monitoring interval
-
RX current laser output power
-
RX minimum laser output power over a performance monitoring interval
-
RX average laser output power over a performance monitoring interval
-
RX maximum laser output power over a performance monitoring interval