Configuring Custom Clocking for CTP Bundles (CTPView)

The custom clocking configuration allows you to configure the source for all clocks and specify which clocks are used to sample and transmit data. The configuration provides complete control over how clocks are used, and we recommend that you have a good understanding of circuit and system clocking before you use this configuration.

You can use custom clocking to:

  • Configure the interface to use nonstandard clock configurations that meet the timing needs of your application.

  • Configure asymmetric clocks.

  • Create special configurations for devices such as tactical radios.

Before you begin:

  • Log in to the CTPView software at least at the Net_Admin level.

  • Connect the CTPView server to the CTP device for which you want to configure bundles.

To configure custom clocking for CTP bundles using CTPView:

  1. In the side pane, select Bundle > Configuration.
  2. Run your mouse over the Display and Select an Existing Bundle bar.
  3. In the table of bundles, select the bundle that you want to modify.
  4. Under Port Options in the Clock Cfg field, select Custom.
  5. Select Custom Clocking Options Show to display custom clocking parameters and configure the parameters as described in Table 1.

    The options vary depending on the I/F Type selected.

  6. Click Click to Submit Bundle AND Port Changes.
Table 1: CTP Bundle Custom Clocking Settings in CTPView
Field Function Your Action

DDS Frequency

Specifies a fixed frequency for the Direct Digital Synthesizer (DDS).

Enter a number from 1 through 2,147,483,647 Hz.

DDS Post Divider

Specifies the divider for the DDS.

Enter a number from 0 through 4.

DDS Source

Specifies the clock source for the DDS.

Select one:

  • USER—The clock is recovered from the user equipment.

  • ADAP—DDS uses adaptive clocking to recover the clock signal from the remote CTP device.

  • AUTO—Use for the autobaud feature. This setting enables the monitoring of OAM packets for the terminal timing (TT) frequency at the other end and processing to accommodate frequency changes that are detected.

DIV Source

Specifies the source for the divider clock. The DIV clock is an alternative clock generator for the bundle, and its output clock is an even integer divider of its source clock.

The divider is used to configure asymmetric circuits.

For example, if the source clock is 512 KHz, the output of the DIV clock can be 256 KHz, 128 KHz, 85.333 KHz, and so on.

Select one:

  • DDS—Direct digital synthesizer clock generator.

  • OSC—Oscillator system clock.

DIV Clk Divider

Specifies the divider clock value. The clock value of the DIV source is divided by this value to obtain the output clock value of the DIV clock.

Enter an even number from 2 through 64,000.

ST Net Bound I/F Clock

Specifies the clock used for Send Timing on the network bound interface.

Select one:

  • OFF—No clock is used.

  • DDS—Direct digital synthesizer clock generator.

  • TT—Transmit timing clock. The interface clock signal from the DTE to the DCE (CTP device). The TT clock is used only if the bundle is configured as the DCE.

  • DIV—Divider clock generator.

  • ST—Send timing clock. The interface clock signal from the DCE to the DTE (CTP device). The ST clock is used only if the bundle is configured as the DTE.

RF Net Bound I/F Clock

Specifies the clock used for Receive Frequency on the network bound interface.

Select one:

  • OFF—No clock is used.

  • DDS—Direct digital synthesizer clock generator.

  • TT—Transmit timing clock. The interface clock signal from the DTE to the DCE (CTP device). The TT clock is used only if the bundle is configured as the DCE.

  • DIV—Divider clock generator.

  • ST—Send timing clock. The interface clock signal from the DCE to the DTE (CTP device). The ST clock is used only if the bundle is configured as the DTE.

RX Net Bound SCC Clock

Specifies the clock used for the Receive Data path on the network bound serial communications controller (SCC).

Select one:

  • OFF—No clock is used.

  • DDS—Direct digital synthesizer clock generator.

  • TT—Transmit timing clock. The external transmit clock used to provide clocking from the CTP device to the user equipment.

  • DIV—Divider clock generator.

  • ST—Send timing clock. The interface clock signal from the user equipment to the CTP device.

RT I/F Bound I/F Clock

Specifies the clock used for Receive Timing on the interface bound interface.

Select one:

  • OFF—No clock is used.

  • DDS—Direct digital synthesizer clock generator.

  • TT—Transmit timing clock. The external transmit clock used to provide clocking from the CTP device to the user equipment.

  • DIV—Divider clock generator.

  • ST—Send timing clock. The interface clock signal from the user equipment to the CTP device.

TX I/F Bound SCC Clock

Specifies the clock used for the Transmit Data path on the interface bound serial communications controller (SCC).

Select one:

  • OFF—No clock is used.

  • DDS—Direct digital synthesizer clock generator.

  • TT—Transmit timing clock. The external transmit clock used to provide clocking from the CTP device to the user equipment.

  • DIV—Divider clock generator.

  • ST—Send timing clock. The interface clock signal from the user equipment to the CTP device.