alarm (chassis)
Syntax
alarm { interface-type { alarm-name (ignore |red | yellow); } }
Hierarchy Level
[edit chassis], [edit chassis interconnect-device name], [edit chassis node-group name]
Description
Configure the chassis alarms and whether they trigger a red or yellow alarm, or
whether they are ignored. Red alarm conditions light the RED ALARM
LED on either the router’s craft interface or the switch’s LCD screen and trigger an
audible alarm if one is connected to the contact on the craft interface or LCD
screen. Yellow alarm conditions light the YELLOW ALARM
LED on
either the router’s craft interface or the switch’s LCD screen and trigger an
audible alarm if one is connected to the craft interface or LCD screen.
To configure more than one alarm, include multiple
alarm-name
lines.
Options
alarm-name
—Alarm
condition. For
example, input1
, input2
ignore
—The specified alarm condition does not set off any alarm.
interface-type
—Type of interface on which you are
configuring the alarm:
psm
,
fpc
, atm
,
ethernet
, sonet
, or t3
.
red
—The specified alarm condition sets off a red alarm.
yellow
—The specified alarm condition sets off a yellow alarm.
Required Privilege Level
interface—To view this statement in the configuration.
interface-control—To add this statement to the configuration.
Release Information
Statement introduced before Junos OS Release 7.4.