request chassis fpc slc
Syntax
request chassis fpc fpc-slot slc slc-id (offline | restart | online)
Description
(Applies to the base system or BSYS). Start, stop or restart the sub line cards (SLCs).
On BSYS, entering the request chassis fpc fpc-slot offline/restart/online
command initiates
the offline/online/restart process of all the SLCs (sub line cards)
of the selected line card (FPC). On GNF, entering the request
chassis fpc fpc-slot offline/restart/online
command initiates the offline/online/restart process of only those
SLCs that are assigned to the selected GNF.
Options
fpc-slot | Specify the line card slot. |
slc-id | Specify the SLC you want to take offline, bring online or restart. |
Required Privilege Level
View
Release Information
Command introduced in Junos OS Release 21.1R1.