request chassis beacon
Syntax (EX Series)
request chassis beacon <fpc slot-number (off | on)> <fpc slot-number (off | on) timer minutes> <fpc slot-number pic-slot slot-number port port-number (off | on)> <fpc slot-number pic-slot slot-number port port-number (off | on) timer minutes>
Syntax (QFX Series)
This is the general syntax for the QFX Series of switches. The exact syntax and options are different depending on the specific model of QFX switch and Junos OS release.
request chassis beacon <all (off | on)> <fpc slot-number (off | on)> <interconnect-device name (cb slot-number | fpc slot-number | (off | on)> <node-device name (off | on)>
Syntax (PTX Series)
request chassis beacon <all (off | on)> <fpc slot-number (off | on)> <interconnect-device name (cb slot-number | fpc slot-number | (off | on)> <node-device name (off | on)>
request chasis beacon
is not supported on the PTX10001-36MR.
Description
(QFX Series switches only) Enable or disable the beacon LED on a QFX Series device.
(EX Series switches only) Supports the following for one or all network port status LEDs on a specified FPC:
-
Enable the beacon for:
-
5 minutes (default)
-
A specified number of minutes (1 through 120)
-
-
Disable the beacon:
-
Instantly
-
After a specified number of minutes (1 through 120) is over
Note:To turn the beacon on or off on a Virtual Chassis, you must issue the
request chassis beacon
command on the primary switch in the Virtual Chassis. Also, when specifying the FPC slot number, you must use the target Virtual Chassis member number. -
Options
all | Turn the beacon LED either on or off on all QFabric system Interconnect and Node devices. |
cb slot-number | Turn the beacon LED either on or off on the Control Board of the QFX3008-I Interconnect device. |
fpc slot-number | Turn all beacon LEDs on the specified FPC either on or off. |
fpc slot-number pic-slot slot-number port port-number | Turn the beacon LED for the specified port either on or off. |
interconnect-device name | Turn the beacon LED either on or off on the Interconnect device. |
node-device name | Turn the beacon LED either on or off on the Node device. |
off | Turn the specified beacon LEDs off. |
on | Turn the specified beacon LEDs on. |
timer minutes | Turn the beacon LEDs on for the specified number of minutes or off after the specified number of minutes elapses.
|
Required Privilege Level
maintenance
Output Fields
When you enter this command, you are provided feedback on the status of your request.
Sample Output
- request chassis beacon fpc on (EX Series and QFX Series Switches)
- request chassis beacon fpc on timer (EX Series Switches)
- request chassis beacon fpc pic-slot port on (EX Series Switches)
- request chassis beacon fpc pic-slot port on timer (EX Series Switches)
- request chassis beacon node-device (QFabric System)
- request chassis beacon on interconnect-device fpc (QFabric System)
- request chassis beacon fpc 0 on (PTX Router)
request chassis beacon fpc on (EX Series and QFX Series Switches)
user@switch> request chassis beacon fpc 0 on Beacon set to ON
request chassis beacon fpc on timer (EX Series Switches)
user@switch> request chassis beacon fpc 0 on timer 10 Beacon set to ON
request chassis beacon fpc pic-slot port on (EX Series Switches)
user@switch> request chassis beacon fpc 0 pic-slot 0 port 1 on Beacon set to ON
request chassis beacon fpc pic-slot port on timer (EX Series Switches)
user@switch> request chassis beacon fpc 0 pic-slot 0 port 1 on timer 10 Beacon set to ON
request chassis beacon node-device (QFabric System)
user@switch> request chassis beacon node-device node1 on node1 ON
request chassis beacon on interconnect-device fpc (QFabric System)
user@switch> request chassis beacon on interconnect-device fpc 2 FPC 2 ON
request chassis beacon fpc 0 on (PTX Router)
user@switch> request chassis beacon fpc 0 on FPC 0 ON
Release Information
Command introduced in Junos OS Release 11.1.